Auflistung nach Autor:in "Heye, Tobias"
Gerade angezeigt 1 - 4 von 4
- Treffer pro Seite
- Sortieroptionen
Publikation The energy consumption of radiology. Energy- and cost-saving opportunities for CT and MRI operation(Radiological Society of North America, 24.03.2020) Heye, Tobias; Knoerl, Roland; Wehrle, Thomas; Mangold, Daniel; Cerminara, Alessandro; Loser, Michael; Plumeyer, Martin; Merkle, Elmar; Degen, Markus; Lüthy, Rahel; Brodbeck, DominiqueBackground Awareness of energy efficiency has been rising in the industrial and residential sectors but only recently in the health care sector. Purpose To measure the energy consumption of modern CT and MRI scanners in a university hospital radiology department and to estimate energy- and cost-saving potential during clinical operation. Materials and Methods Three CT scanners, four MRI scanners, and cooling systems were equipped with kilowatt-hour energy measurement sensors (2-Hz sampling rate). Energy measurements, the scanners’ log files, and the radiology information system from the entire year 2015 were analyzed and segmented into scan modes, as follows: net scan (actual imaging), active (room time), idle, and system-on and system-off states (no standby mode was available). Per-examination and peak energy consumption were calculated. Results The aggregated energy consumption imaging 40 276 patients amounted to 614 825 kWh, dedicated cooling systems to 492 624 kWh, representing 44.5% of the combined consumption of 1 107 450 kWh (at a cost of U.S. $199 341). This is equivalent to the usage in a town of 852 people and constituted 4.0% of the total yearly energy consumption at the authors' hospital. Mean consumption per CT examination over 1 year was 1.2 kWh, with a mean energy cost (±standard deviation) of $0.22 ± 0.13. The total energy consumption of one CT scanner for 1 year was 26 226 kWh ($4721 in energy cost). The net consumption per CT examination over 1 year was 3580 kWh, which is comparable to the usage of a two-person household in Switzerland; however, idle state consumption was fourfold that of net consumption (14 289 kWh). Mean MRI consumption over 1 year was 19.9 kWh per examination, with a mean energy cost of $3.57 ± 0.96. The mean consumption for a year in the system-on state was 82 174 kWh per MRI examination and 134 037 kWh for total consumption, for an energy cost of $24 127. Conclusion CT and MRI energy consumption is substantial. Considerable energy- and cost-saving potential is present during nonproductive idle and system-off modes, and this realization could decrease total cost of ownership while increasing energy efficiency.01A - Beitrag in wissenschaftlicher ZeitschriftPublikation Gamification of electronic learning in radiology education to improve diagnostic confidence and reduce error rates(American Roentgen Ray Society, 2020) Winkel, David J.; Brantner, Philipp; Lutz, Jonas; Korkut, Safak; Linxen, Sebastian; Heye, TobiasOBJECTIVE. The purpose of this study is to validate an electronic learning, or e-learning, concept featuring gamification elements, rapid case reading, and instant feedback. SUBJECTS AND METHODS. An e-learning concept was devised that offered game levels for the purpose of providing training in the detection of pneumothorax in 195 cases, with questions read in rapid succession and instant feedback provided for each case. The user's task was to locate the pneumothorax on chest radiographs and indicate its presence by clicking a mouse. The game level design included an entry test consisting of 15 cases, training levels with increasing difficulty that involved 150 cases, and a final test that including 30 cases (the 15 cases from the entry test plus 15 new cases). A total of 126 candidates were invited via e-mail to participate and were asked to complete a survey before and after playing the game, which is known as RapRad. The level of diagnostic confidence and the error rate before and after playing the game were compared using a Wilcoxon signed rank test. RESULTS. Fifty-nine of 126 participants (47%) responded to the first survey and finished the game. Of these 59 participants, 29 (49%) responded to the second survey after completing the game. Diagnostic confidence in pneumothorax detection improved significantly, from a mean (± SD) score of 4.3 ± 2.1 on the entry test to a final score of 7.3 ± 2.1 (p < 0.01) after playing RapRad, with the score measured on a 10-point scale, with 10 denoting the highest possible score. Of the participants, 93% indicated that they would use the game for learning purposes again, and 87% indicated that they had fun using RapRad (7% had a neutral response and 6% had a negative response). The error rate (i.e., the number of failed attempts to answer a question correctly) significantly decreased from 39% for the entry test to 22% for the final test (p < 0.01). CONCLUSION. Our e-learning concept is capable of improving diagnostic confidence, reducing error rates in training pneumothorax detection, and offering fun in interaction with the platform.01A - Beitrag in wissenschaftlicher ZeitschriftPublikation RapRad - A New E-learning Concept with Rapid Case Reading and Instant Feedback to Reduce Chance in Radiology Education(27.11.2016) Brantner, Philipp; Steiner, Fabienne; Korkut, Safak; Linxen, Sebastian; Merkle, Elmar; Heye, Tobias06 - PräsentationPublikation Tourney: A game-based learning approach for the recognition of uncommon pathologies in Radiology(10/2017) Korkut, Safak; Lutz, Jonas; Brantner, Philipp; Heye, Tobias; Steiner, Fabienne; Linxen, Sebastian; Dornberger, Rolf04B - Beitrag Konferenzschrift