The accuracy of dynamic contour tonometry over soft contact lenses

Thumbnail
Öffnen
2013 GogniatOptom Vis Sci.pdf (331.9Kb)
Autor/Autorin
Gogniat, Fabrice
Steinegger, Daniela
Nosch, Daniela
Joos, Roland E
Goldschmidt, Michael
Datum
02.2013
Metadata
Zur Langanzeige
Type
01 - Zeitschriftenartikel, Journalartikel oder Magazin
Zusammenfassung
Purpose. Dynamic contour tonometry (DCT) has been shown to measure the intraocular pressure (IOP) independently of corneal thickness. This study aimed to investigate if DCT remains accurate when the IOP measurement is taken over soft contact lenses (CLs) of different thicknesses and material characteristics. Methods. This was a prospective clinical study that included 42 patients. Subject age was 22 to 59 years (26.5 T 6.3 years). Intraocular pressure and ocular pulse amplitude (OPA) measurements were taken under topical anesthesia without CLs and over various daily disposable CLs with j0.50, +5.00, and j5.00 diopters (D) in hydrogel (Nelfilcon A) and in silicone hydrogel (Narafilcon A) materials. Results. No statistically significant differences were found when comparing the IOP measurements obtained using either of the different CL powers of j0.50 or j5.00 D, irrespective of which CL material was being used. However, the difference of 0.62mmHg observed when the Nelfilcon Awith a power of +5.00Dwas used turned out to be highly statistically significant (p = 0.0002), whereas the Narafilcon Awith the same power of +5.00 D, with a small difference of j0.16 mm Hg, was not. Regarding OPA measurements, no significant differences were found between measurements with and without CL neither for different materials nor for change in dioptrical power (F = 0, p = 1.000). Conclusions. This study showed good reliability of IOP and OPA measurements over CLs with varying thickness profiles and different soft materials when using the DCT. Only a small but statistically significant difference of 0.62mmHg was found for the IOP measurement with the hydrogel CL of +5.00 D compared with ‘‘no CL.’’
URI
http://hdl.handle.net/11654/11505
http://dx.doi.org/10.26041/fhnw-148
Übergeordnetes Werk
Optometry & Vision Science
Jahrgang
90
Ausgabe
2
Seiten
125-130
Zitation

Stöbern

Gesamter BestandBereiche & SammlungenErscheinungsdatumAutoren/AutorinnenTitelThemenDiese SammlungErscheinungsdatumAutoren/AutorinnenTitelThemen

Mein Benutzerkonto

EinloggenRegistrieren
Erweiterter Export: CSVErweiterter Export: RISErweiterter Export: BibTeX

Kontakt

Fachhochschule Nordwestschweiz FHNW
Vizepräsidium Hochschulentwicklung
Bahnhofstrasse 6
5210 Windisch

E-Mail: irf@fhnw.ch

Über das IRF

Das IRF ist das digitale Repositorium der Fachhochschule Nordwestschweiz FHNW. Es enthält Publikationen, studentische Arbeiten und Projekte.

Links

IRF Handbuch
Liste der IRF Power User
Feedbackformular

www.fhnw.ch | Impressum | Datenschutz | Urheberrecht | IRF-Reglement