  • Publikation
    Gravity ventilation for interior bathrooms
    (IOP Publishing, 01.12.2023) Hall, Monika; Gerber, Vincent; Geissler, Achim [in: Journal of Physics: Conference Series]
    Based on the extensive experience of a building cooperative with interior bathroom gravity (shaft) ventilation in existing apartment buildings, the replacement buildings constructed at the same location are also equipped with gravity ventilation. The aim of the project described here is to demonstrate the possibilities and limitations of gravity ventilation in one of the new replacement buildings by means of monitoring. Detailed monitoring over a complete year recorded the behaviour and effectiveness of the gravity ventilation in all seasons. In winter, gravity ventilation leads to higher air change rates in interior bathrooms than in summer. In general, humidity can be removed with gravity ventilation except in summer, when after a shower the bathroom door stays closed for 24 h. In summer when the indoor and ambient temperature is the same the gravity ventilation does not work. In this case, the interior bathroom should be ventilated by the main apartment ventilation, e.g., while the bathroom door and other room doors and windows are open at the same time. In summer, doors and windows are often open and the gravity ventilation summer problem can be viewed as negligible. Therefore, gravity ventilation is a good alternative to other ventilation systems in interior bathrooms.
    01A - Beitrag in wissenschaftlicher Zeitschrift
  • Publikation
    Determine the heat demand of existing buildings with machine learning
    (IOP Publishing, 01.12.2023) Hofmann, Joachim Werner; Amoser, Christian; Geissler, Achim; Hall, Monika [in: Journal of Physics: Conference Series]
    The renovation rate of existing buildings plays a major role in the Swiss Energy Strategy 2050+. To increase this rate, there must be a simple and cost-effective method to determine the heat demand of existing buildings. In this paper, the generation of such a method, based on the Swiss cantonal building energy certificate (GEAK) database with the help of machine learning (ML), is studied. The aim of the project was to develop a ML model which allows the heat demand of existing buildings to be determined quickly with a minimal set of parameters. The comparison of the GEAK building envelope class for single family houses calculated with the new ML model and the original GEAK classes shows that approximately 62 % have the same class, 32 % differ by one class and 6 % by two classes. The ML model is a good starting point for further refinements and developments.
    01A - Beitrag in wissenschaftlicher Zeitschrift
  • Publikation
    Schwerkraftlüftung – Low-tech Lüftung für innenliegende Bäder in einem Mehrfamilienhaus
    (Brenet, 12.09.2022) Hall, Monika; Geissler, Achim; Gerber, Vincent; Sattler, Michael; Bichsel, Jürg; Rudel, Roman; Steiger, Olivier; Tillenkamp, Frank [in: SustainDesign user friendly and resilient design with appropriate technology]
    Über ein detailliertes Monitoring wird die Wirksamkeit der Schwerkraftlüftung in acht innenliegenden Bädern in einem Mehrfamilien Neubau bestimmt. Jeweils vier Bäder liegen übereinander. Jedes Bad verfügt über ein eigenes Zu- und Abluftrohr. Frischluft wird auf Kellerhöhe gefasst und die Fortluft auf Firsthöhe abgegeben. Weil bei der Schwerkraftlüftung der Luftaustausch auf Grund von Druckunterschieden am Gebäude erfolgt, ist er nicht bzw. kaum steuerbar und saisonal unterschiedlich. Daher erfolgt das Monitoring über ein komplettes Jahr, um das Verhalten in allen Jahreszeiten zu erfassen. Die Messungen zwischen März und Juli 2022 zeigen, dass sich die rel. Luftfeuchtigkeit der Bäder im Mittel zwischen ca. 45-65 % bewegt. Fallbetrachtungen zeigen, dass kurzzeitige hohe Feuchtebelastungen (bis ~98 % bei einem Duschvorgang) nach ca. 30 min bei offener Badezimmertüre und mindestens einem geöffneten Fenster und entsprechender, geöffneter Zimmertüre wieder auf ca. 60 % reduziert sind (manuelle Fensterlüftung, Juni). Bei einer geschlossenen Badezimmertüre dauert es infolge der Schwerkraftlüftung ca. 2.5 Stunden, um nach zwei Duschvorgängen auf 60 % rel. Luftfeuchtigkeit zu sinken (März). Letztgenannter Fall zeigt, dass durch die Schwerkraftlüftung eine ausreichende Feuchteabfuhr erfolgt.
    04B - Beitrag Konferenzschrift
  • Publikation
    Baumaterialien für Städte im Klimawandel. Materialkatalog mit Empfehlungen
    (Bundesamt für Wohnungswesen (BWO), 16.06.2022) Hoffmann, Caroline; Geissler, Achim
    Städte erwärmen sich stärker als ländliche Gegenden. Dieser Materialkatalog zeigt auf, mit welchen Baumaterialien sich die Umwelt weniger erwärmt. Das Nachschlagewerk richtet sich an Planerinnen und Planer sowie Bauträgerschaften, die Gebäude im urbanen Raum erstellen oder sanieren.
    05 - Forschungs- oder Arbeitsbericht
  • Publikation
    Comparison of flexibility factors and introduction of a flexibility classification using advanced heat pump control
    (MDPI, 13.12.2021) Hall, Monika; Geissler, Achim [in: Energies]
    With the increasing use of renewable energy, the energy flexibility of buildings becomes increasingly important regarding grid support. Therefore, there is a need to describe this flexibility in a concise manner. For the characterization of building energy flexibility, flexibility factors can be used. The comparison of a selection of existing flexibility factors shows that they are not easy to use or understand for designers and users. A simplification is necessary. The aim of this study is to introduce a flexibility classification that is easy to understand and shows in an easy way if a building already uses the lowest energy cost level or if further improvement is possible. The classification expresses the annual energy costs in colored classes: green (class A) for lowest up to red (class D) for highest level. Basically, the flexibility classes can be derived for any metric of interest, in this paper examples are shown for energy costs and CO2eq emissions. The results given are based on the simulation of load management scenarios with different penalty signals applied for the heat pump operation of a residential building.
    01A - Beitrag in wissenschaftlicher Zeitschrift
  • Publikation
    Comparison of flexibility factors for a residential building
    (IOP Publishing, 18.11.2021) Hall, Monika; Geissler, Achim [in: Journal of Physics: Conference Series]
    Buildings that are able to shift their loads without comfort restraints are important for the ongoing transformation of the power supply. This flexibility potential can be expressed in flexibility factors. The usefulness of four factors is investigated based on load control for the heat pump of a small apartment building according to electricity prices (high/low tariffs, spot market prices), CO2eq emissions share in the grid and a restricted operation period during daytime. The calculation methodology of the presented flexibility factors GSC, RIP, FF and FI is very different. RIP and FF are preferable because they have defined valid ranges which makes them easier to understand. Current electricity prices force the heat pump operation mainly into the night. The optimization of CO2eq emissions encourages operation mainly during the day. The optimization goals costs or CO2eq emissions thus lead to opposing heat pump operation times and can currently therefore not both be met simultaneously.
    01A - Beitrag in wissenschaftlicher Zeitschrift
  • Publikation
    Die zerstörungsfreie Messung des U-Wertes von Aussenbauteilen. Eine Anwendungshilfe
    (EnergieSchweiz, 01.10.2021) Hoffmann, Caroline; Geissler, Achim
    U-Wert Messungen vor Ort eigenen sich für Gebäude, bei denen die Konstruktion unbekannt ist und eine zerstörungsfreie, sichere Aussage zu den thermischen Eigenschaften getroffen werden soll. Die entsprechenden Messgeräte sind am Markt erhältlich und zielen auf eine breite Anwendung. Ziel des Projektes ist es, eine praxisorientierte Anwendungshilfe für die U-Wert Messung vor Ort zu erstellen. Als Basis dienen in-situ U-Wert Messungen und vergleichende Messungen im Labor, die mit drei unterschiedlichen Messgeräten durchgeführt werden. Ergänzend dazu werden Simulationen erstellt und Kontakt- und Haftmittel zur Befestigung der Sensoren an den zu messenden Bauteilen getestet. Untersucht werden schwere, homogene Bauteile, damit beziehen sich die Hinweise hauptsächlich auf diesen Bauteiltyp.
    05 - Forschungs- oder Arbeitsbericht
  • Publikation
    Passive window ventilation openings in every-day use
    (Elsevier, 28.08.2021) Hoffmann, Caroline; Geissler, Achim; Hauri, Claudia; Huber, Heinrich [in: Building and Environment]
    The integration of passive window ventilation openings (PWVO, small air inlets integrated in the window frame) with additional exhaust fans in the kitchen and bathroom(s) can ensure a user-independent basic air change rate in dwellings. The project reported on herein is focused on how well buildings with PWVO work in real life.
    01A - Beitrag in wissenschaftlicher Zeitschrift
  • Publikation
    FENLEG: Fensterlüfter in der etappierten Gebäudesanierung. Ist der Einsatz erfolgreich?
    (Bundesamt für Energie BFE, 04.03.2021) Hoffmann, Caroline; Geissler, Achim; Hauri, Claudia; Huber, Heinrich; Primas, Alex; Niederberger, Sven; Jasari, Jasin
    Der Einbau von Fensterlüftern (als passive Lüftungselemente, die in das Fenster integriert sind oder im direkten Zusammenhang mit dem Fenster stehen) zusammen mit einer permanenten oder zeitgesteuerten Lüftung über Abluftventilatoren in Küche und Bad kann eine nutzerunabhängige Grundlüftung sicherstellen. Soll diese Grundlüftung nur den Feuchteschutz (Vermeidung von Schimmel) sicherstellen, so sind die erforderlichen Luftmengen kleiner, als wenn der hygienische Luftwechsel angestrebt wird. Der Fokus der vorliegenden Forschungsarbeit ist die Schimmelfreiheit. Ziel ist es herauszufinden, wie sich Fensterlüfter in Wohngebäuden in der Praxis bewähren. Insgesamt werden vier neu errichtete und acht sanierte Gebäudetypen (28 Gebäude) mittels Gebäudebegehungen, einer Bewohnerbefragung und Messungen in acht Wohnungen untersucht.
    05 - Forschungs- oder Arbeitsbericht
  • Publikation
    Konditionierung von Kellerräumen in Wohngebäuden. Schlussbericht
    (EnergieSchweiz, 10.01.2020) Hauri, Claudia; Huber, Heinrich; Jasari, Jasin; Näf, Michael; Hoffmann, Caroline; Geissler, Achim
    Das Ziel des Projektes ist es technisch interessierten Bauherrschaften, Planern, ausführenden Betrieben, Verwaltungen und Bewirtschaftern unabhängige und frei zugängliche Informationen zur energetisch optimalen Konditionierung von Kellerraumen in Wohnbauten zur Verfügung zu stellen. Neben diesem Bericht werden daher Merkblätter in deutscher, französischer und italienischer Sprache erstellt und auf der Webseite von EnergieSchweiz publiziert. Im Projekt werden Kellerräumen bei Neubauten, bei sanierten und unsanierten Gebäuden behandelt. Hierfür werden mit thermisch dynamischen Simulationen vier Varianten zur Konditionierung bezüglich Schimmelrisiko und Energieverbrauch untersucht.
    05 - Forschungs- oder Arbeitsbericht