Auflistung nach Autor:in "Martins dos Santos, Sebastiao"
Gerade angezeigt 1 - 2 von 2
- Treffer pro Seite
- Sortieroptionen
Publikation Characterization and intercomparison of aerosol absorption photometers. result of two intercomparison workshops(Copernicus, 2011) Müller, Thomas; Henzing, Bas; de Leeuw, Gerrit; Wiedensohler, Alfred; Alastuey, Andrés; Angelov, H.; Bizjak, Milan; Collaud Coen, Martine; Engström, J. E.; Gruening, Carsten; Hillamo, Risto; Hoffer, András; Imre, Kornélia; Ivanow, Petko; Jennings, Stephen G.; Sun, Junying; Kalivitis, Nikos; Karlsson, Hanna; Komppula, Mikka; Laj, Paolo; Li, S.-M.; Lunder, Chris; Marinoni, Angela; Martins dos Santos, Sebastiao; Moerman, Marcel; Nowak, Andreas; Ogren, John A.; Petzold, Andreas; Pichon, Jean Marc; Rodriquez, Sergio; Sharma, Sangeeta; Sheridan, Patrick J.; Teinilä, Kimmo; Tuch, Thomas; Viana, Mar; Virkkula, Aki; Weingartner, Ernest; Wilhelm, R.; Wang, YaqiangAbsorption photometers for real time application have been available since the 1980s, but the use of filter-based instruments to derive information on aerosol properties (absorption coefficient and black carbon, BC) is still a matter of debate. Several workshops have been conducted to investigate the performance of individual instruments over the intervening years. Two workshops with large sets of aerosol absorption photometers were conducted in 2005 and 2007. The data from these instruments were corrected using existing methods before further analysis. The inter-comparison shows a large variation between the responses to absorbing aerosol particles for different types of instruments. The unit to unit variability between instruments can be up to 30% for Particle Soot Absorption Photometers (PSAPs) and Aethalometers. Multi Angle Absorption Photometers (MAAPs) showed a variability of less than 5%. Reasons for the high variability were identified to be variations in sample flow and spot size. It was observed that different flow rates influence system performance with respect to response to absorption and instrumental noise. Measurements with non absorbing particles showed that the current corrections of a cross sensitivity to particle scattering are not sufficient. Remaining cross sensitivities were found to be a function of the total particle load on the filter. The large variation between the response to absorbing aerosol particles for different types of instruments indicates that current correction functions for absorption photometers are not adequate.01A - Beitrag in wissenschaftlicher ZeitschriftPublikation Intercomparison study of six HTDMAs. results and recommendations(Copernicus, 24.07.2009) Duplissy, Jonathan; Gysel, Martin; Sjogren, S.; Meyer, Nickolas; Good, Nicholas; Kammermann, Lukas; Michaud, Vincent; Weigel, Ralf; Martins dos Santos, Sebastiao; Gruening, Carsten; Villani, P.; Laj, Paolo; Sellegri, Karine; Metzger, Axel; McFiggans, Gordon B.; Wehrle, Günther; Richter, René; Dommen, Josef; Ristovski, Zoran; Baltensperger, Urs; Weingartner, ErnestWe report on an intercomparison of six different hygroscopicity tandem differential mobility analysers HTDMAs). These HTDMAs are used worldwide in laboratory experiments and field campaigns to measure the water uptake of aerosol particles and have never been intercompared. After an investigation of the different design of the instruments with their advantages and inconveniencies, the methods for calibration, validation and data analysis are presented. Measurements of nebulised ammonium sulphate as well as of secondary organic aerosol generated from a smog chamber were performed. Agreement and discrepancies between the instruments and to the theory are discussed, and final recommendations for a standard instrument are given, as a benchmark for laboratory or field experiments to ensure a high quality of HTDMA data.01A - Beitrag in wissenschaftlicher Zeitschrift