Hochschule für Technik und Umwelt FHNW
Dauerhafte URI für den Bereichhttps://irf.fhnw.ch/handle/11654/35
Listen
16 Ergebnisse
Bereich: Suchergebnisse
Publikation Do MCH prisms change asthenopic complaints when reading?(DOZ-Verlag, 28.06.2024) Joss, Joëlle; Jainta, StephaniePurpose. Asthenopic symptoms mostly occur during demanding near-sighted tasks and are related to binocular symptoms (e.g. heterophoria), among others. Correction of symptomatic heterophoria with prismatic glasses is one way to treat the symptoms. This study investigates the effect of wearing a horizontal prismatic correction for 6 months. Material and Methods. A total of 87 subjects were assigned to a heterophoric prism group (N=32), a heterophoric control group (N= 31) or an orthophoric control group (N= 24) according to their MCH heterophoria. In the heterophoric prism group, the subjects were prescribed glasses with a prismatic correction for 6 months according to their distance correction; in contrast, the subjects in the heterophoric control group had to wear glasses without prismatic correction for the same period. The effect of the prisms on complaints due to asthenopic symptoms was investigated by comparing the total sum obtained in the CISS questionnaire at the beginning of the study and after 6 months (before and after wearing glasses) for the 3 groups. Results. A (long-term) prism effect was not apparent in the CISS total score. In both the heterophoric prism group and in the heterophoric control group, the CISS total score increased slightly and non-significantly after 6 months. When considering the heterophoric subjects with an increased CISS score at baseline, a nevertheless slight but non-significant decrease of symptoms was observed. All changes were observed in both the heterophoric prism group and the heterophoric control group. An additional analysis using binocular profiles showed a reduction in symptoms by numbers and specifically for subjects with reduced vergence facility. Conclusion. Wearing an individual, horizontal prismatic correction had no effect on the overall CISS-score for our test subjects. Further methods that allow a systematic recording of symptoms and optometric parameters are probably necessary to observe an effect. These could be binocular profiles that classify individuals according to their binocular parameters.01A - Beitrag in wissenschaftlicher ZeitschriftPublikation Verändern MKH-Prismen den binokularen Vorteil beim Lesen?(DOZ-Verlag, 2022) Joss, Joëlle; Jainta, StephanieZweck. Beim Lesen mit beiden Augen stellt sich ein binokularer Vorteil (kürzere Lese- und Fixationszeiten im Vergleich zu monokularem Lesen), welcher durch Prozesse der motorischen und sensorischen Fusion zustande kommt, ein. Der binokulare Vorteil beim Lesen ist zum Teil von der individuellen horizontalen Heterophorie abhängig und damit stellte sich die Frage, ob sich prismatische Korrektionen (bestimmt nach der MKH-Methode, zum Ausgleich einer Heterophorie) auf den binokularen Vorteil oder auf Parameter der binokularen Koordination beim Lesen auswirken. Material und Methoden. Wir haben die binokularen Augenbewegungen von 54 Personen mit einer individuellen horizontalen Heterophorie beim Lesen vermessen (Eyelink II): für (1) monokular, (2) binokular, (3) binokular mit Disparität (entsprechend MKH-Prisma) und (4) binokular mit Disparität nach sechs Monaten präsentierte, deutschsprachige Sätze (insg. 120). In der sechsmonatigen Pause zwischen Messung (3) und (4) trugen 29 Personen Brillen mit prismatischen Korrektionen, während 25 Personen als Kontrollgruppe fungierten. Ergebnisse. Unsere Daten zeigten einen klaren, signifikantenVorteil für binokulares Lesen für alle Personen, ohne dass eine kurzfristige Präsentation einer individuellen Disparität (analog eines MKH-Prismas) daran etwas änderte. Erst nach einer Prismentragezeit von sechs Monaten zeigte sich zusätzlich ein tendenziell größerer binokularer Vorteil in der „Prismengruppe“ im Vergleich zur „Kontrollgruppe“. Parallel dazu nahm die Kopplung der Augen (Diskonjunktion) leicht zu und die objektive Fixationsdisparität nahm signifikant ab. Fazit. Das Tragen einer individuellen prismatischen, horizontalen Korrektion (MKH) hatte für unsere Studienteilnehmer*innen einen Einfluss auf die binokulare Koordination beim Lesen und erhöhte gleichzeitig den binokularen Vorteil. Dieser eher mittel- bis langfristige Effekt von prismatischen Korrektionen ist neu und sollte in weiteren Studien vertieft untersucht werden.01A - Beitrag in wissenschaftlicher ZeitschriftPublikation Do standard optometric measures predict binocular coordination during reading?(Bern Open Publishing, 21.01.2021) Joss, Joëlle; Jainta, StephanieIn reading, binocular eye movements are required for optimal visual processing and thus, in case of asthenopia or reading problems, standard orthoptic and optometric routines check individual binocular vision by a variety of tests. The present study therefore examines the predictive value of such standard measures of heterophoria, accommodative and vergence facility, AC/A-ratio, NPC and symptoms for binocular coordination parameters during reading. Binocular eye movements were recorded (EyeLink II) for 65 volunteers during a typical reading task and linear regression analyses related all parameters of binocular coordination to all above-mentioned optometric measures: while saccade disconjugacy was weakly predicted by vergence facility (15% explained variance), vergence facility, AC/A and symptoms scores predicted vergence drift (31%). Heterophoria, vergence facility and NPC explained 31% of fixation disparity and first fixation duration showed minor relations to symptoms (18%). In sum, we found only weak to moderate relationships, with expected, selective associations: dynamic parameter related to optometric tests addressing vergence dynamics, whereas the static parameter (fixation disparity) related mainly to heterophoria. Most surprisingly, symptoms were only loosely related to vergence drift and fixation duration, reflecting associations to a dynamic aspect of binocular eye movements in reading and potentially non-specific, overall but slight reading deficiency. Thus, the efficiency of optometric tests to predict binocular coordination during reading was low – questioning a simple, straightforward extrapolation of such test results to an overlearned, complex task.01A - Beitrag in wissenschaftlicher ZeitschriftPublikation Einblick. Nach mehr als zwei Jahren Forschung gibt es Neuigkeiten zur Wirkung prismatischer Korrekturen beim Lesen(Galledia, 10/2022) Joss, Joëlle; Jainta, Stephanie01B - Beitrag in Magazin oder ZeitungPublikation Relating asthenopic symptoms to optometric measures and parameters of binocular vision(08/2022) Joss, Joëlle; Jainta, StephanieAsthenopic symptoms are related to heterophoria and problems of binocular vision. In a recent paper, we showed that vergence drift and fixation durations are related to symptoms (CISS-questionnaire), but optometric measures such as heterophoria, vergence or accommodative facility, AC/A-ratio or NPC did not significantly add to the explained variance of asthenopia. We re-analysed our data, in which binocular eye movements were recorded (EyeLink II) for 64 participants, and linear regression analyses related all parameters of binocular coordination (objective heterophoria, vergence drift, saccade disconjugacy, fixation disparity and fixation duration), and the above-mentioned optometric tests to 4 symptoms factors (eye comfort, reading process, image quality and fatigue), which we identified by a factor analysis of the CISS-questionnaire. Objective heterophoria and fixation duration predicted 20% of the variance in symptoms concerning the reading process (factor 2). Furthermore, fixation duration seems to be slightly, but not significantly, related to symptoms addressing fatigue (factor 4), whereas optometric tests are not significantly related to any asthenopia factor. Overall, objective measures during reading relate to asthenopic symptoms, however the lack of asthenopic symptoms prediction by daily optometric parameters is still unexplained. Therefore, further research is needed to find out suited optometric parameters to infer asthenopic symptoms.06 - PräsentationPublikation Binocular advantages in reading revisited. Attenuating effects of individual horizontal heterophoria(Bern Open Publishing, 09.12.2019) Jainta, Stephanie; Joss, JoëlleReading with two eyes necessitates efficient processes of binocular vision, which provide a single percept of the text. These processes come with a binocular advantage: binocular reading shows shorter average fixation durations and sentence reading times when compared to monocular reading. A couple of years ago, we showed for a small sample (N=13) that binocular advantages critically relate to the individual heterophoria (the resting state of vergence). In the present, large-scale replication we collected binocular eye movements (Eyelink II) for 94 participants who read 20 sentences monocularly and 20 sentences binocularly. Further, individual heterophorias were determined using three different optometric standards: objective eye tracking (EyeLink II at 60 cm), Maddox wing test (at 30 cm) and measures following the “Guidelines for the application of the Measuring and Correcting Methodology after H.-J. Haase” (MCH; at 6 m). Binocular eye movements showed typical pattern and we replicated (1) binocular advantages of about 25 ms for average fixation durations and (2) a reduction in binocular advantages when heterophoria increased – but only when heterophoria was identified by EyeLink II or Maddox wing measures; MCH measures of heterophoria did not affect binocular advantages in reading. For large heterophorias binocular reading even turned into a disadvantage. Implications for effect estimations and optometric testing will be discussed.01A - Beitrag in wissenschaftlicher ZeitschriftPublikation Hornhautsensibilität Teil 1: Grundlagen und Messung(2013) Nosch, DanielaDie Hornhautsensibilität wird durch eine neurologische Reaktion der frei liegenden Nervenfaserenden im Hornhautepithel bestimmt. Diese registrieren mechanische, chemische und thermische Reizungen und versorgen somit die Hornhaut mit einem wichtigen Schutzmechanismus vor schädlichen Einflüssen aus der Umwelt: Eine mechanische Reizung bewirkt eine Empfindung von Schmerz, eine elektrische Reizung verursacht Schmerzen und Irritation, ein kalter Stimulus wird als kühlend wahrgenommen, ein warmer Stimulus hingegen verursacht Irritation, während eine chemische Reizung als brennend oder gar stechender Schmerz empfunden wird. In diesem Artikel werden die Wissensgrundlagen zu den oberflächlichen Hornhautnerven zusammengefasst: deren Rolle bei der Erhaltung eines gesunden Stoffwechsels der Hornhaut, ihre Innervation, die verschiedenen schmerzempfindlichen cornealen Nerventypen und ihre Nervenenden, die Morphologie des epithelialen subbasalen Nervenplexus und schließlich die Messung der Hornhautsensibilität.01B - Beitrag in Magazin oder ZeitungPublikation Periphere Epitheliale Corneale Hypertrophie (PECH) beim Tragen weicher hydrophiler Kontaktlinsen(05/2016) Bronner, Rainer; Nosch, DanielaPeripheral epithelial corneal hyperfluorescence (PECH) in daily soft contact lens (CL) wear is described by three case reports. In vivo confocal microscopy (IVCM) measurements show the presence of epithelial corneal hypertrophy on affected eyes. A statistical analysis of a group of patients with PECH in comparison to a control group suggests a hypoxic cause for PECH. Further clinical studies with balanced patient populations are required to confirm these findings, as the population of this study group was affected by a selection bias.01B - Beitrag in Magazin oder ZeitungPublikation Hornhautsensibilität Teil 2: Der Einfluss von Kontaktlinsen(01/2014) Nosch, DanielaDie Messung der Hornhautsensibilität ermöglicht eine Beurteilung der Funktionstüchtigkeit der schmerzempfindlichen oberflächlichen Hornhautnerven. Daraus ergeben sich wichtige Hinweise auf die Gesundheit der Hornhaut im Verlauf eines Erkrankungsprozesses, während der Heilungsphase nach einer Verletzung oder einem refraktiv-chirurgischen Eingriff, sowie beim Kontaktlinsentragen. Die Nervenenden in der Hornhaut und Bindehaut sind über ein komplexes Feedback-Netzwerk (unter Aktivierung von Hirnstamm Regelkreisen) mit den Tränendrüsen und dem Musculus orbicularis oculi verbunden, um die Gesundheit der Augenvorderfläche und den Tränenfilm jederzeit zu überwachen und zu erhalten. Für die Regulierung des Heilungsprozesses nach Verletzungen lösen sie die Freigabe von trophischen Substanzen (Neuropeptide und Neurotrophine) aus. Dieser Beitrag fasst die publizierte Literatur über den Einfluss des Kontaktlinsentragens zusammen und erläutert, welche Auswirkungen verschiedene Kontaktlinsenmaterialien und Tragemodi haben.01B - Beitrag in Magazin oder ZeitungPublikation Hornhautsensibilität Teil 3: Das Trockene Auge, Keratokonus, refraktive Chirurgie, Keratoplastik und systemische Erkrankungen(02/2014) Nosch, DanielaDie vorangegangenen beiden Artikel machten deutlich, welche wichtige Rolle die oberflächlichen Nerven im cornealen epithelialen sub-basalen Nervenplexus für eine gesunde Hornhaut spielen und wie sie in ihrer Reaktionsfähigkeit durch das Tragen von Kontaktlinsen beeinflusst werden können. Dieser dritte Artikel handelt von möglichen Änderungen der Hornhautsensibilität bei der Entwicklung des trockenen Auges (und in seinem weiteren Krankheitsverlauf), bei Keratokonus, refraktiver Chirurgie, Keratoplastik sowie infolge systemischer Erkrankungen, wie beispielsweise der peripheren Neuropathie bei Diabetes.01B - Beitrag in Magazin oder Zeitung