Hochschule für Technik und Umwelt FHNW

Dauerhafte URI für den Bereichhttps://irf.fhnw.ch/handle/11654/35

Listen

Bereich: Suchergebnisse

Gerade angezeigt 1 - 6 von 6
  • Vorschaubild
    Publikation
    High order dynamic mode decomposition for mechanical vibrations and modal analysis
    (HAL, 2023) Tuor, Andreas; Canzani, Nico; Rüggeberg, Tobias; Gorenflo, Stefan; Simons, Gerd; Bättig, Bruno; Iseli, Daniel
    05 - Forschungs- oder Arbeitsbericht
  • Vorschaubild
    Publikation
    Development of a waveguide-based interferometer for the measurement of trace substances
    (Zenodo, 07.11.2023) Weingartner, Ernest; Bilal, Jonas; Steigmeier, Peter; Jundt, Gregor; Häusler, Samuel; Lenner, Miklós; Flöry, Nikolaus; Bittner, Matthias; Betschon, Felix
    Photonic integration on a chip has the potential to develop new low-cost, high-performance sensing devices. A proof of concept of the sensing capabilities of a waveguide-based photothermal interferometer for the measurement of traces of light-absorbing substances (soot particles, gases) has been achieved. The measurement principle can also be extended to a wide range of other applications such as refractive index measurements, or vibration/distance sensors. A unique feature is that the waveguide technology allows for a passive operation of the interferometer, i.e., no quadrature point control is required.
    04B - Beitrag Konferenzschrift
  • Publikation
    Air cleaners and respiratory infections in schools. A modeling study using epidemiological, environmental, and molecular data
    (Oxford University Press, 30.12.2023) Banholzer, Nicolas; Jent, Philipp; Bittel, Pascal; Zürcher, Kathrin; Furrer, Lavinia; Bertschinger, Simon; Weingartner, Ernest; Ramette, Alban; Egger, Matthias; Hascher, Tina; Fenner, Lukas
    AbstractBackgroundUsing a multiple-measurement approach, we examined the real-world effectiveness of portable HEPA-air filtration devices (air cleaners) in a school setting.MethodsWe collected environmental (CO2, particle concentrations), epidemiological (absences related to respiratory infections), audio (coughing), and molecular data (bioaerosol and saliva samples) over seven weeks during winter 2022/2023 in two Swiss secondary school classes. Using a cross-over study design, we compared particle concentrations, coughing, and the risk of infection with vs without air cleaners.ResultsAll 38 students (age 13−15 years) participated. With air cleaners, mean particle con-centration decreased by 77% (95% credible interval 63%−86%). There were no differences in CO2levels. Absences related to respiratory infections were 22 without vs 13 with air cleaners. Bayesian modeling suggested a reduced risk of infection, with a posterior probability of 91% and a relative risk of 0.73 (95% credible interval 0.44−1.18). Coughing also tended to be less frequent (posterior probability 93%). Molecular analysis detected mainly non-SARS-CoV-2 viruses in saliva (50/448 positive), but not in bioaerosols (2/105 positive) or HEPA-filters (4/160). The detection rate was similar with vs without air cleaners. Spatiotemporal analysis of positive saliva samples identified several likely transmissions.ConclusionsAir cleaners improved air quality, showed a potential benefit in reducing respiratory infections, and were associated with less coughing. Airborne detection of non-SARS-CoV-2 viruses was rare, suggesting that these viruses may be more difficult to detect in the air. Future studies should examine the importance of close contact and long-range transmission, and the cost-effectiveness of using air cleaners.
    01A - Beitrag in wissenschaftlicher Zeitschrift
  • Vorschaubild
    Publikation
    A novel measurement system for unattended, in situ characterization of carbonaceous aerosols
    (Copernicus, 22.12.2023) Keller, Alejandro; Specht, Patrick; Steigmeier, Peter; Weingartner, Ernest
    Carbonaceous aerosol is a relevant constituent of the atmosphere in terms of climate and health impacts. Nevertheless, measuring this component poses many challenges. There is currently no simple and sensitive commercial technique that can reliably capture its totality in an unattended manner, with minimal user intervention, for extended periods of time. To address this issue we have developed the fast thermal carbon totalizator (FATCAT). Our system captures an aerosol sample on a rigid metallic filter and subsequently analyses it by rapidly heating the filter directly, through induction, to a temperature around 800°C. The carbon in the filter is oxidized and quantified as CO2 in order to establish the total carbon (TC) content of the sample. The metallic filter is robust, which solves filter displacement or leakage problems, and does not require a frequent replacement like other measurement techniques. The limit of detection of our system using the 3σ criterion is TC =0.19 µg-C (micrograms of carbon). This translates to an average ambient concentration of TC =0.32 µg-C m^−3 and TC =0.16 µg-C m^−3 for sampling interval of 1 or 2 h respectively using a sampling flow rate of 10 L min^−1. We present a series of measurements using a controlled, well-defined propane flame aerosol as well as wood-burning emissions using two different wood-burning stoves. Furthermore, we complement these measurements by coating the particles with secondary organic matter by means of an oxidation flow reactor. Our device shows a good correlation (correlation coefficient, R^2>0.99) with well-established techniques, like mass measurements by means of a tapered element oscillating microbalance and TC measurements by means of thermal–optical transmittance analysis. Furthermore, the homogeneous fast-heating of the filter produces fast thermograms. This is a new feature that, to our knowledge, is exclusive of our system. The fast thermograms contain information regarding the volatility and refractoriness of the sample without imposing an artificial fraction separation like other measurement methods. Different aerosol components, like wood-burning emissions, soot from the propane flame and secondary organic matter, create diverse identifiable patterns.
    01A - Beitrag in wissenschaftlicher Zeitschrift
  • Vorschaubild
    Publikation
    Waveguide based passively demodulated photothermal interferometer for light absorption measurements of trace substances
    (Optica Publishing Group, 2023) Visser, Bradley; Bilal, Jonas; Flöry, Nikolaus; Wipf, Manuela; Steigmeier, Peter; Rüggeberg, Tobias; Betschon, Felix; Weingartner, Ernest
    01A - Beitrag in wissenschaftlicher Zeitschrift
  • Vorschaubild
    Publikation
    Quantum logical controlled-NOT gate in a lithium niobate-on-insulator photonic quantum walk
    (Institute of Physics Publishing, 17.11.2023) Chapman, Robert J; Häusler, Samuel; Finco, Giovanni; Kaufmann, Fabian; Grange, Rachel
    The two-qubit controlled-NOT gate is one of the central entangling operations in quantum information technology. The controlled-NOT gate for single photon qubits is normally realized as a network of five individual beamsplitters on six optical modes. Quantum walks (QWs) are an alternative photonic architecture involving arrays of coupled waveguides, which have been successful for investigating condensed matter physics, however, have not yet been applied to quantum logical operations. Here, we engineer the tight-binding Hamiltonian of an array of lithium niobate-on-insulator waveguides to experimentally demonstrate the two-qubit controlled-NOT gate in a QW. We measure the two-qubit transfer matrix with 0.938 ± 0.003 fidelity, and we use the gate to generate entangled qubits with 0.945 ± 0.002 fidelity by preparing the control photon in a superposition state. Our results highlight a new application for QWs that use a compact multi-mode interaction region to realize large multi-component quantum circuits.
    01A - Beitrag in wissenschaftlicher Zeitschrift