Wintgens, Thomas

Lade...
Profilbild
E-Mail-Adresse
Geburtsdatum
Projekt
Organisationseinheiten
Berufsbeschreibung
Nachname
Wintgens
Vorname
Thomas
Name
Wintgens, Thomas

Suchergebnisse

Gerade angezeigt 1 - 2 von 2
  • Publikation
    Tradeoff between micropollutant abatement and bromate formation during ozonation of concentrates from nanofiltration and reverse osmosis processes
    (Elsevier, 2022) Wünsch, Robin; Hettich, Timm; Prahtel, Marlies; Thomann, Michael; Wintgens, Thomas; Von Gunten, Urs [in: Water Research]
    Water treatment with nanofiltration (NF) or reverse osmosis (RO) membranes results in a purified permeate and a retentate, where solutes are concentrated and have to be properly managed and discharged. To date, little is known on how the selection of a semi-permeable dense membrane impacts the dissolved organic matter in the concentrate and what the consequences are for micropollutant (MP) abatement and bromate formation during concentrate treatment with ozone. Laboratory ozonation experiments were performed with standardized concentrates produced by three membranes (two NFs and one low-pressure reverse osmosis (LPRO) membrane) from three water sources (two river waters and one lake water). The concentrates were standardized by adjustment of pH and concentrations of dissolved organic carbon, total inorganic carbon, selected micropollutants (MP) with a low to high ozone reactivity and bromide to exclude factors which are known to impact ozonation. NF membranes had a lower retention of bromide and MPs than the LPRO membrane, and if the permeate quality of the NF membrane meets the requirements, the selection of this membrane type is beneficial due to the lower bromate formation risks upon concentrate ozonation. The bromate formation was typically higher in standardized concentrates of LPRO than of NF membranes, but the tradeoff between MP abatement and bromate formation upon ozonation of the standardized concentrates was not affected by the membrane type. Furthermore, there was no difference for the different source waters. Overall, ozonation of concentrates is only feasible for abatement of MPs with a high to moderate ozone reactivity with limited bromate formation. Differences in the DOM composition between NF and LPRO membrane concentrates are less relevant than retention of MPs and bromide by the membrane and the required ozone dose to meet a treatment target.
    01A - Beitrag in wissenschaftlicher Zeitschrift
  • Publikation
    Micropollutants as internal probe compounds to assess UV fluence and hydroxyl radical exposure in UV/H2O2 treatment
    (Elsevier, 18.02.2021) Wünsch, Robin; Mayer, Carina; Plattner, Julia; Eugster, Fabienne; Wülser, Richard; Gebhardt, Jens; Hübner, Uwe; Canonica, Silvio; von Gunten, Urs; Wintgens, Thomas [in: Water Research]
    Organic micropollutants (MPs) are increasingly detected in water resources, which can be a concern for human health and the aquatic environment. Ultraviolet (UV) radiation based advanced oxidation pro- cesses (AOP) such as low-pressure mercury vapor arc lamp UV/H2O2 can be applied to abate these MPs. During UV/H2O2 treatment, MPs are abated primarily by photolysis and reactions with hydroxyl radicals (•OH), which are produced in situ from H2O2 photolysis. Here, a model is presented that calculates the applied UV fluence (Hcalc) and the •OH exposure (CT•OH,calc) from the abatement of two selected MPs, which act as internal probe compounds. Quantification of the UV fluence and hydroxyl radical exposure was generally accurate when a UV susceptible and a UV resistant probe compound were selected, and both were abated at least by 50 %, e.g., iopamidol and 5-methyl-1H-benzotriazole. Based on these key parameters a model was developed to predict the abatement of other MPs. The prediction of abatement was verified in various waters (sand filtrates of rivers Rhine and Wiese, and a tertiary wastewater efflu- ent) and at different scales (laboratory experiments, pilot plant). The accuracy to predict the abatement of other MPs was typically within ±20 % of the respective measured abatement. The model was further as- sessed for its ability to estimate unknown rate constants for direct photolysis (kUV,MP) and reactions with •OH (k•OH,MP). In most cases, the estimated rate constants agreed well with published values, considering the uncertainty of kinetic data determined in laboratory experiments. A sensitivity analysis revealed that in typical water treatment applications, the precision of kinetic parameters (kUV,MP for UV susceptible and k•OH,MP for UV resistant probe compounds) have the strongest impact on the model’s accuracy
    01A - Beitrag in wissenschaftlicher Zeitschrift