Brönnimann, Benedikt

Lade...
Profilbild
E-Mail-Adresse
Geburtsdatum
Projekt
Organisationseinheiten
Berufsbeschreibung
Nachname
Brönnimann
Vorname
Benedikt
Name
Brönnimann, Benedikt

Suchergebnisse

Gerade angezeigt 1 - 3 von 3
  • Publikation
    Kontinuierliche Ethoxylierung
    (25.04.2024) Zogg, Andreas; Zahnd, This; Brönnimann, Benedikt
    Modellbasiertes Sicherheitskonzept für die Entwicklung einer kontinuierlichen Ethoxylierung. Modellvalidierung mittels kontinuierlichem Kalorimeter innerhalb einer Glove-Box.
    06 - Präsentation
  • Publikation
    Development of a novel measurement setup to study and predict electrostatic discharges in agitated glass‐lined vessels
    (Wiley, 12.02.2024) Brönnimann, Benedikt; Egli‐Tedesco, Daniel; Schwenzfeuer, Klaus; Zogg, Andreas [in: Helvetica Chimica Acta]
    Two glass lined reactors in a launch platform facility operated by Syngenta have been damaged during the crystallization of an organic compound due to electrostatic discharges. The goal of this work was to design and commission a novel setup to measure charges and currents generated by this slurry in a laboratory‐scale reactor. An improved and more sophisticated setup was then proposed for possible implementation in Syngenta's own laboratories. With this novel setup, the electrostatic charging of stirred suspensions involving nonconductive solvents could be accurately measured in the context of a case study that involved the suspension that led to liner damages in the production facilities of Syngenta.
    01A - Beitrag in wissenschaftlicher Zeitschrift
  • Publikation
    Development of a setup to study electrostatic discharges
    (Hochschule für Life Sciences FHNW, 2023) Brönnimann, Benedikt; Zogg, Andreas
    Two glass lined reactors in a launch platform facility operated by Syngenta have been damaged during a crystallization-process of an organic compound due to electrostatic discharges. The goal of this thesis was to design and commission a unique setup to measure charges and currents generated by such suspensions in a laboratory-scale reactor. These measurements made it possible to then calculate and estimate resulting discharge energies. An improved and more sophisticated setup was then proposed for possible implementation in their own laboratories. With this novel setup, the electrostatic charging of stirred suspensions involving non conductive solvents could be accurately measured in the context of a case study that involved the suspension that led to liner damages in the production facilities of Syngenta.
    11 - Studentische Arbeit