The new LassoLoop360° technique for biomechanically superior tissue grip
No Thumbnail Available
Authors
Müller, Sebastian
Author (Corporation)
Publication date
2019
Typ of student thesis
Course of study
Type
01A - Journal article
Editors
Editor (Corporation)
Supervisor
Parent work
Knee Surgery, Sports Traumatology, Arthroscopy
Special issue
DOI of the original publication
Link
Series
Series number
Volume
27
Issue / Number
12
Pages / Duration
3962-3969
Patent number
Publisher / Publishing institution
Springer
Place of publication / Event location
Edition
Version
Programming language
Assignee
Practice partner / Client
Abstract
PurposeSuprapectoral tenodesis is a frequently used technique for treating pathologies of the long head of the biceps bra-chii (LHBB) tendon. However, so far, no Gold Standard treatment exist. Hence, the arthroscopic LassoLoop360 (LL360) technique is introduced aiming to provide secure fixation and improved biomechanical properties. It was hypothesized, that the LL360 technique would show superior biomechanical response to cyclic loading and ultimate load-to-failure testing compared to the commonly used simple Lasso Loop (SLL).MethodsTwenty-two porcine superficial flexor digitorum tendons were prepared using a No. 2 suture according to either the SLL or the LL360 technique. Displacement after cyclic loading (1.000 cycles) between 5 and 30 N, ultimate load-to-failure (ULTF), mode of failure as well as the construct stiffness were tested.ResultsSignificantly less displacement was found in the LL360 group (SLL 2.25 ± 0.51 mm; LL360 1.67 ± 0.37 mm; p = 0.01). Ultimate Load to Failure was significantly higher in the LL360 (168.6 ± 29.6 N) as compared to the SLL (124.1 ± 25.8 N, p = 0.02). The LL360 also revealed a significant higher stiffness compared to the SLL (SLL 13.1 ± 0.9 N/mm vs. LL360 19.1 ± 1.0 N/mm, p < 0.001). The most common mode of failure was the suture cutting through the tendon, with a significantly less suture cutting through for the LL360 compared with the SLL (p < 0.05).ConclusionThe LassoLoop360-technique offers superior biomechanical characteristics regarding the tendon-suture-interface compared to the SLL. In the initial healing phase, the suture-tendon-interface is the most vulnerable part of the tendon-suture-anchor construct, the aim of this new technique is to reduce this weakest part of the chain (Ponce et al., Am J Sports Med 39:188–194, 2011). This technique may therefore be beneficial for arthroscopic suprapectoral biceps tenodesis at the entrance of the bicipital groove
Keywords
Long Head of the biceps brachii (LHBB) tendon, Suprapectoral tenodesis, Biomechanics, Biomechanical testing, Single-Lasso-Loop (SLL), LassoLoop360(LL360)
Subject (DDC)
Event
Exhibition start date
Exhibition end date
Conference start date
Conference end date
Date of the last check
ISBN
ISSN
0942-2056
1433-7347
1433-7347
Language
English
Created during FHNW affiliation
Yes
Strategic action fields FHNW
Publication status
Published
Review
Peer review of the complete publication
Open access category
License
Citation
MÜLLER, Sebastian und Michael DE WILD, 2019. The new LassoLoop360° technique for biomechanically superior tissue grip. Knee Surgery, Sports Traumatology, Arthroscopy. 2019. Bd. 27, Nr. 12, S. 3962–3969. DOI 10.1007/s00167-019-05604-1. Verfügbar unter: https://irf.fhnw.ch/handle/11654/30258