Experimental validation of 4D log file‐based proton dose reconstruction for interplay assessment considering amplitude‐sorted 4DCTs
Loading...
Authors
Spautz, Saskia
Jakobi, Annika
Meijers, Arturs
Peters, Nils
Löck, Steffen
Troost, Esther G.C.
Richter, Christian
Stützer, Kristin
Author (Corporation)
Publication date
11.04.2022
Typ of student thesis
Course of study
Type
01A - Journal article
Editors
Editor (Corporation)
Supervisor
Parent work
Medical Physics
Special issue
DOI of the original publication
Link
Series
Series number
Volume
49
Issue / Number
6
Pages / Duration
3538-3549
Patent number
Publisher / Publishing institution
Wiley
Place of publication / Event location
Edition
Version
Programming language
Assignee
Practice partner / Client
Abstract
Purpose
The unpredictable interplay between dynamic proton therapy delivery and target motion in the thorax can lead to severe dose distortions. A fraction-wise four-dimensional (4D) dose reconstruction workflow allows for the assessment of the applied dose after patient treatment while considering the actual beam delivery sequence extracted from machine log files, the recorded breathing pattern and the geometric information from a 4D computed tomography scan (4DCT). Such an algorithm capable of accounting for amplitude-sorted 4DCTs was implemented and its accuracy as well as its sensitivity to input parameter variations was experimentally evaluated.
Methods
An anthropomorphic thorax phantom with a movable insert containing a target surrogate and a radiochromic film was irradiated with a monoenergetic field for various 1D target motion forms (sin, sin4) and peak-to-peak amplitudes (5/10/15/20/30 mm). The measured characteristic film dose distributions were compared to the respective sections in the 4D reconstructed doses using a 2D γ-analysis (3 mm, 3%); γ-pass rates were derived for different dose grid resolutions (1 mm/3 mm) and deformable image registrations (DIR, automatic/manual) applied during the 4D dose reconstruction process. In an additional analysis, the sensitivity of reconstructed dose distributions against potential asynchronous timing of the motion and machine log files was investigated for both a monoenergetic field and more realistic 4D robustly optimized fields by artificially introduced offsets of ±1/5/25/50/250 ms. The resulting dose distributions with asynchronized log files were compared to those with synchronized log files by means of a 3D γ-analysis (1 mm, 1%) and the evaluation of absolute dose differences.
Results
The induced characteristic interplay patterns on the films were well reproduced by the 4D dose reconstruction with 2D γ-pass rates ≥95% for almost all cases with motion magnitudes ≤15 mm. In general, the 2D γ-pass rates showed a significant decrease for larger motion amplitudes and increase when using a finer dose grid resolution but were not affected by the choice of motion form (sin, sin4). There was also a trend, though not statistically significant, toward the manually defined DIR for better quality of the reconstructed dose distributions in the area imaged by the film. The 4D dose reconstruction results for the monoenergetic as well as the 4D robustly optimized fields were robust against small asynchronies between motion and machine log files of up to 5 ms, which is in the order of potential network latencies.
Conclusions
We have implemented a 4D log file-based proton dose reconstruction that accounts for amplitude-sorted 4DCTs. Its accuracy was proven to be clinically acceptable for target motion magnitudes of up to 15 mm. Particular attention should be paid to the synchronization of the log file generating systems as the reconstructed dose distribution may vary with log file asynchronies larger than those caused by realistic network delays.
Keywords
Subject (DDC)
600 - Technik, Medizin, angewandte Wissenschaften
Event
Exhibition start date
Exhibition end date
Conference start date
Conference end date
Date of the last check
ISBN
ISSN
0094-2405
2473-4209
2473-4209
Language
English
Created during FHNW affiliation
No
Strategic action fields FHNW
Publication status
Published
Review
Peer review of the complete publication
Open access category
Hybrid
Citation
SPAUTZ, Saskia, Annika JAKOBI, Arturs MEIJERS, Nils PETERS, Steffen LÖCK, Esther G.C. TROOST, Christian RICHTER, Kristin STÜTZER und Antje KNOPF, 2022. Experimental validation of 4D log file‐based proton dose reconstruction for interplay assessment considering amplitude‐sorted 4DCTs. Medical Physics. 11 April 2022. Bd. 49, Nr. 6, S. 3538–3549. DOI 10.1002/mp.15625. Verfügbar unter: https://doi.org/10.26041/fhnw-4850