Container Closure Integrity Testing of Prefilled Syringes,

dc.accessRightsAnonymous
dc.audienceScience
dc.contributor.authorPelaez, Sarah
dc.contributor.authorMahler, Hanns-Christian
dc.contributor.authorKoulov, Atanas
dc.contributor.authorSingh, Satish K.
dc.contributor.authorGermershaus, Oliver
dc.contributor.authorMathaes, Roman
dc.date.accessioned2019-01-25T08:27:43Z
dc.date.available2019-01-25T08:27:43Z
dc.date.issued2018-08
dc.description.abstractPrefilled syringes (PFSs) are increasingly preferred over vials as container closure systems (CCSs) for injectable drug products when facilitated or self-administration is required. However, PFSs are more complex compared to CCSs consisting of vial, rubber stopper, and crimp cap. Container closure integrity (CCI) assurance and verification has been a specific challenge for PFSs as they feature several sealing areas. A comprehensive understanding of the CCS is necessary for an appropriate CCI assessment as well as for packaging development and qualification. A comprehensive CCI assessment of 6 different PFSs from 3 different manufacturers (including 1 polymeric PFS) was conducted using helium leak testing. PFS components were manipulated to systematically assess the contribution of the different sealing areas to CCI, namely rigid needle shield (RNS)/needle, RNS/tip cone, and the individual ribs of a syringe plunger. The polymeric PFS required an equilibrium measurement for accurate container closure integrity testing. The different sealing areas and a single plunger rib were shown to provide adequate CCI. Acceptable tip cap movement until the point of CCI failure was estimated. The assessment of acceptable tip cap movement demonstrated the importance of considering the RNS/tip cone seal design to ensure CCI of the PFS upon post assembly possesses and shipment.
dc.identifier.doihttps://doi.org/10.1016/j.xphs.2018.03.025
dc.identifier.issn0022-3549
dc.identifier.issn1520-6017
dc.identifier.urihttp://hdl.handle.net/11654/27328
dc.issue8
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.relation.ispartofJournal of Pharmaceutical Sciencesen_US
dc.subjectcontainer closure integrity testing
dc.subjectprefilled syringe
dc.subjectprimary syringe
dc.subjectmass spectrometry-based helium leak detection
dc.subjectUSP <1207>
dc.titleContainer Closure Integrity Testing of Prefilled Syringes,
dc.type01A - Beitrag in wissenschaftlicher Zeitschrift
dc.volume107
dspace.entity.typePublication
fhnw.InventedHereYes
fhnw.IsStudentsWorkno
fhnw.PublishedSwitzerlandNo
fhnw.ReviewTypeAnonymous ex ante peer review of a complete publication
fhnw.affiliation.hochschuleHochschule für Life Sciencesde_CH
fhnw.affiliation.institutInstitut für Pharma Technologyde_CH
fhnw.pagination2091-2097
fhnw.publicationOnlineJa
fhnw.publicationStatePublished
relation.isAuthorOfPublication5f661671-2e22-4169-b24b-692dcfd2aed4
relation.isAuthorOfPublication.latestForDiscovery5f661671-2e22-4169-b24b-692dcfd2aed4
Dateien