Membrane-supported liquid-liquid extraction. Where do we stand today?
dc.accessRights | Anonymous | * |
dc.contributor.author | Riedl, Wolfgang | |
dc.date.accessioned | 2022-02-22T11:23:34Z | |
dc.date.available | 2022-02-22T11:23:34Z | |
dc.date.issued | 2021-02 | |
dc.description.abstract | Thanks to advances in materials science and manufacturing technology, membranes are now available for stable liquid-liquid extraction processes. Rigorous calculation models can be used to calculate the membrane areas required for a specific separation task as well as to optimize the module design. Rapid tests can determine the basic suitability and kinetic parameters. Thus, the general requirements for exploiting the specific advantages of this separation technology in technical applications are fulfilled. | en_US |
dc.identifier.doi | 10.1002/cben.202000032 | |
dc.identifier.issn | 2196-9744 | |
dc.identifier.uri | https://irf.fhnw.ch/handle/11654/33321 | |
dc.identifier.uri | https://doi.org/10.26041/fhnw-4111 | |
dc.issue | 1 | en_US |
dc.language.iso | en_US | en_US |
dc.publisher | Wiley | en_US |
dc.relation.ispartof | ChemBioEng Reviews | en_US |
dc.rights | Attribution-NonCommercial-NoDerivs 3.0 United States | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | en_US |
dc.subject | Mass transfer model | en_US |
dc.subject | Membrane-assisted liquid-liquid extraction | en_US |
dc.subject | Membrane contactors | en_US |
dc.title | Membrane-supported liquid-liquid extraction. Where do we stand today? | en_US |
dc.type | 01A - Beitrag in wissenschaftlicher Zeitschrift | |
dc.volume | 8 | en_US |
dspace.entity.type | Publication | |
fhnw.InventedHere | Yes | en_US |
fhnw.IsStudentsWork | no | en_US |
fhnw.ReviewType | Anonymous ex ante peer review of a complete publication | en_US |
fhnw.affiliation.hochschule | Hochschule für Life Sciences FHNW | de_CH |
fhnw.affiliation.institut | Institut für Chemie und Bioanalytik | de_CH |
fhnw.openAccessCategory | Hybrid | en_US |
fhnw.pagination | 6-14 | en_US |
fhnw.publicationState | Published | en_US |
relation.isAuthorOfPublication | dafd470f-df2a-4db5-989c-c7fb0ba40332 | |
relation.isAuthorOfPublication.latestForDiscovery | dafd470f-df2a-4db5-989c-c7fb0ba40332 |
Dateien
Originalbündel
1 - 1 von 1
- Name:
- ChemBioEng Reviews - 2021 - Riedl - Membrane%E2%80%90Supported Liquid%E2%80%90Liquid Extraction Where Do We Stand Today.pdf
- Größe:
- 2.41 MB
- Format:
- Adobe Portable Document Format
- Beschreibung: