Characterization and intercomparison of aerosol absorption photometers. result of two intercomparison workshops

dc.contributor.authorMüller, Thomas
dc.contributor.authorHenzing, Bas
dc.contributor.authorde Leeuw, Gerrit
dc.contributor.authorWiedensohler, Alfred
dc.contributor.authorAlastuey, Andrés
dc.contributor.authorAngelov, H.
dc.contributor.authorBizjak, Milan
dc.contributor.authorCollaud Coen, Martine
dc.contributor.authorEngström, J. E.
dc.contributor.authorGruening, Carsten
dc.contributor.authorHillamo, Risto
dc.contributor.authorHoffer, András
dc.contributor.authorImre, Kornélia
dc.contributor.authorIvanow, Petko
dc.contributor.authorJennings, Stephen G.
dc.contributor.authorSun, Junying
dc.contributor.authorKalivitis, Nikos
dc.contributor.authorKarlsson, Hanna
dc.contributor.authorKomppula, Mikka
dc.contributor.authorLaj, Paolo
dc.contributor.authorLi, S.-M.
dc.contributor.authorLunder, Chris
dc.contributor.authorMarinoni, Angela
dc.contributor.authorMartins dos Santos, Sebastiao
dc.contributor.authorMoerman, Marcel
dc.contributor.authorNowak, Andreas
dc.contributor.authorOgren, John A.
dc.contributor.authorPetzold, Andreas
dc.contributor.authorPichon, Jean Marc
dc.contributor.authorRodriquez, Sergio
dc.contributor.authorSharma, Sangeeta
dc.contributor.authorSheridan, Patrick J.
dc.contributor.authorTeinilä, Kimmo
dc.contributor.authorTuch, Thomas
dc.contributor.authorViana, Mar
dc.contributor.authorVirkkula, Aki
dc.contributor.authorWeingartner, Ernest
dc.contributor.authorWilhelm, R.
dc.contributor.authorWang, Yaqiang
dc.date.accessioned2024-08-13T13:46:56Z
dc.date.available2024-08-13T13:46:56Z
dc.date.issued2011
dc.description.abstractAbsorption photometers for real time application have been available since the 1980s, but the use of filter-based instruments to derive information on aerosol properties (absorption coefficient and black carbon, BC) is still a matter of debate. Several workshops have been conducted to investigate the performance of individual instruments over the intervening years. Two workshops with large sets of aerosol absorption photometers were conducted in 2005 and 2007. The data from these instruments were corrected using existing methods before further analysis. The inter-comparison shows a large variation between the responses to absorbing aerosol particles for different types of instruments. The unit to unit variability between instruments can be up to 30% for Particle Soot Absorption Photometers (PSAPs) and Aethalometers. Multi Angle Absorption Photometers (MAAPs) showed a variability of less than 5%. Reasons for the high variability were identified to be variations in sample flow and spot size. It was observed that different flow rates influence system performance with respect to response to absorption and instrumental noise. Measurements with non absorbing particles showed that the current corrections of a cross sensitivity to particle scattering are not sufficient. Remaining cross sensitivities were found to be a function of the total particle load on the filter. The large variation between the response to absorbing aerosol particles for different types of instruments indicates that current correction functions for absorption photometers are not adequate.
dc.identifier.doi10.5194/amt-4-245-2011
dc.identifier.issn1867-8548
dc.identifier.issn1867-1381
dc.identifier.urihttps://irf.fhnw.ch/handle/11654/46580
dc.identifier.urihttps://doi.org/10.26041/fhnw-9646
dc.issue2
dc.language.isoen
dc.publisherCopernicus
dc.relation.ispartofAtmospheric Measurement Techniques
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.spatialGöttingen
dc.subject.ddc550 - Geowissenschaften
dc.titleCharacterization and intercomparison of aerosol absorption photometers. result of two intercomparison workshops
dc.type01A - Beitrag in wissenschaftlicher Zeitschrift
dc.volume4
dspace.entity.typePublication
fhnw.InventedHereNo
fhnw.ReviewTypeAnonymous ex ante peer review of a complete publication
fhnw.affiliation.hochschuleHochschule für Technik und Umwelt FHNWde_CH
fhnw.affiliation.institutlnstitut für Sensorik und Elektronikde_CH
fhnw.openAccessCategoryGold
fhnw.pagination245-268
fhnw.publicationStatePublished
relation.isAuthorOfPublication05dd9a19-7a24-4325-805a-2d121483b168
relation.isAuthorOfPublication.latestForDiscovery05dd9a19-7a24-4325-805a-2d121483b168
Dateien

Originalbündel

Gerade angezeigt 1 - 1 von 1
Vorschaubild
Name:
amt-4-245-2011.pdf
Größe:
3.98 MB
Format:
Adobe Portable Document Format

Lizenzbündel

Gerade angezeigt 1 - 1 von 1
Kein Vorschaubild vorhanden
Name:
license.txt
Größe:
2.66 KB
Format:
Item-specific license agreed upon to submission
Beschreibung: