Validation and comparative analysis of a contemporary non-contact corneal aesthesiometer
Lade...
Dateien
Autor:in (Körperschaft)
Publikationsdatum
20.04.2026
Typ der Arbeit
Studiengang
Sammlung
Typ
01A - Beitrag in wissenschaftlicher Zeitschrift
Herausgeber:innen
Herausgeber:in (Körperschaft)
Betreuer:in
Übergeordnetes Werk
Journal of Clinical Medicine
Themenheft
Diagnosis and Treatment of Ocular Surface Diseases
DOI der Originalpublikation
Link
Zugehörige Forschungsdaten
Reihe / Serie
Reihennummer
Jahrgang / Band
15
Ausgabe / Nummer
8
Seiten / Dauer
Patentnummer
Verlag / Herausgebende Institution
MDPI
Verlagsort / Veranstaltungsort
Auflage
Version
Programmiersprache
Abtretungsempfänger:in
Praxispartner:in/Auftraggeber:in
Zusammenfassung
Background: Corneal sensitivity is a key indicator of ocular surface health. This prospective, cross-sectional study evaluated agreement between corneal sensitivity thresholds obtained from equivalent stimulus settings on a contemporary, enhanced dual-temperature non-contact corneal aesthesiometer (NCCA) and a previously validated (standard) device.
Methods: Central corneal sensitivity thresholds were measured in the right eyes of healthy participants using both devices. Participants with previous ocular surgery, laser treatment, trauma, contact lens wear, diabetes, or peripheral neuropathy were excluded. Sensitivity thresholds were determined using a forced-response, double-staircase protocol. Inter-device agreement was assessed using Bland–Altman analysis, and consistency was assessed using intraclass correlation coefficients.
Results: Median corneal sensitivity thresholds in 51 healthy participants (32 female, 19 male; mean age: 33 ± 14 years) did not differ between enhanced (0.23 [0.18 to 0.38]) and standard (0.25 [0.15 to 0.35]) NCCA instruments (p = 0.73). Bland–Altman analysis demonstrated moderate inter-device agreement, with a mean difference of −0.01 mbar (95% limits of agreement: −0.41 to 0.39 mbar). Linear regression analysis identified greater measurement discrepancies at higher thresholds (p < 0.05), indicating greater variability in individuals with reduced corneal sensitivity.
Conclusions: The enhanced NCCA yields reliable corneal sensitivity measures for a room-temperature stimulus and acceptable agreement with the existing (standard) model.
Schlagwörter
Fachgebiet (DDC)
Veranstaltung
Startdatum der Ausstellung
Enddatum der Ausstellung
Startdatum der Konferenz
Enddatum der Konferenz
Datum der letzten Prüfung
ISBN
ISSN
2077-0383
Sprache
Englisch
Während FHNW Zugehörigkeit erstellt
Ja
Zukunftsfelder FHNW
Publikationsstatus
Veröffentlicht
Begutachtung
Peer-Review der ganzen Publikation
Open Access-Status
Gold
Zitation
Xue, A. L., Britten-Jones, A. C., Zhuang, D., Jennings, C. J., Müntz, A., Misra, S. L., Downie, L. E., & Craig, J. P. (2026). Validation and comparative analysis of a contemporary non-contact corneal aesthesiometer. Journal of Clinical Medicine, 15(8). https://doi.org/10.3390/jcm15083145