Effects of the test aerosol on the performance of periodic technical inspection particle counters

dc.contributor.authorVasilatou, Konstantina
dc.contributor.authorWälchli, Christian
dc.contributor.authorAuderset, Kevin
dc.contributor.authorBurtscher, Heinz
dc.contributor.authorHammer, Tobias
dc.contributor.authorGiechaskiel, Barouch
dc.contributor.authorMelas, Anastasios
dc.date.accessioned2025-05-26T07:53:04Z
dc.date.issued2023-08
dc.description.abstractA new scheme for periodical technical inspection (PTI) of diesel-engine exhaust based on the measurement of particle number (PN) concentration was recently introduced in several European countries. PN concentration is measured directly at the tailpipe using portable particle counters known as PN-PTI. The technical specifications of these instruments are defined at a national level, and the type-examination and verification procedures differ considerably among European countries. In this study, we examined how the choice of test aerosol can affect the counting efficiency profile of the PN-PTI sensors, the majority of which are based on diffusion charging (DC). Carbonaceous aerosols were produced by combustion and spark discharge generators, sodium chloride (NaCl) particles were generated from aqueous solutions using several commercially available nebulizers and silver particles were produced by a silver particle generator. In most cases, the response of DC-based sensors depended strongly on the morphology of the test particles. Comparison with a Euro 3 diesel engine without a diesel particle filter (DPF) indicated that the combustion aerosols generated by combustion generators were the best proxy for soot emitted by diesel vehicle engines. On the contrary, the use of NaCl and spark discharge particles as test aerosols led in some cases to an over- or underestimation of the PN concentration by up to about a factor of two. Moreover, our results showed that the response of each type of DC-based sensors is individual and, as a result, it is impossible to determine a generally applicable factor to correct for the impact of the test aerosol properties. We recommend that the verification of PN-PTI instruments be preferably performed with soot particles produced by a combustion generator (identical or similar to the one used during the type-examination) in order to avoid corrections for the impact of the material on the response of the instruments.
dc.identifier.doi10.1016/j.jaerosci.2023.106182
dc.identifier.issn0021-8502
dc.identifier.urihttps://irf.fhnw.ch/handle/11654/51482
dc.identifier.urihttps://doi.org/10.26041/fhnw-12702
dc.language.isoen
dc.publisherElsevier
dc.relation.ispartofJournal of Aerosol Science
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subject.ddc620 - Ingenieurwissenschaften und Maschinenbau
dc.subject.ddc624 - Ingenieurbau und Umwelttechnik
dc.titleEffects of the test aerosol on the performance of periodic technical inspection particle counters
dc.type01A - Beitrag in wissenschaftlicher Zeitschrift
dc.volume172
dspace.entity.typePublication
fhnw.InventedHereNo
fhnw.ReviewTypeAnonymous ex ante peer review of a complete publication
fhnw.affiliation.hochschuleHochschule für Technik und Umwelt FHNWde_CH
fhnw.affiliation.institutInstitut für Sensorik und Elektronikde_CH
fhnw.openAccessCategoryHybrid
fhnw.pagination106182
fhnw.publicationStatePublished
relation.isAuthorOfPublication7bcf855e-5eb6-4a5f-ba90-e93bec5fd0a6
relation.isAuthorOfPublication.latestForDiscovery7bcf855e-5eb6-4a5f-ba90-e93bec5fd0a6
Dateien

Originalbündel

Gerade angezeigt 1 - 1 von 1
Lade...
Vorschaubild
Name:
1-s2.0-S0021850223000472-main.pdf
Größe:
7.47 MB
Format:
Adobe Portable Document Format

Lizenzbündel

Gerade angezeigt 1 - 1 von 1
Lade...
Vorschaubild
Name:
license.txt
Größe:
2.66 KB
Format:
Item-specific license agreed upon to submission
Beschreibung: