Deposition uniformity and particle size distribution of ambient aerosol collected with a rotating drum impactor
Vorschaubild nicht verfügbar
Autor:innen
Bukowiecki, Nicolas
Richard, Agnes
Furger, Markus
Aguirre, Myriam
Huthwelker, Thomas
Lienemann, Peter
Gehrig, Robert
Baltensperger, Urs
Autor:in (Körperschaft)
Publikationsdatum
30.06.2009
Typ der Arbeit
Studiengang
Typ
01A - Beitrag in wissenschaftlicher Zeitschrift
Herausgeber:innen
Herausgeber:in (Körperschaft)
Betreuer:in
Übergeordnetes Werk
Aerosol Science and Technology
Themenheft
DOI der Originalpublikation
Link
Reihe / Serie
Reihennummer
Jahrgang / Band
43
Ausgabe / Nummer
9
Seiten / Dauer
891-901
Patentnummer
Verlag / Herausgebende Institution
Taylor & Francis
Verlagsort / Veranstaltungsort
Auflage
Version
Programmiersprache
Abtretungsempfänger:in
Praxispartner:in/Auftraggeber:in
Zusammenfassung
Rotating drum impactors (RDI) are cascade type impactors used for size and time resolved aerosol sampling, mostly followed by spectrometric analysis of the deposited material. They are characterized by one rectangular nozzle per stage and are equipped with an automated stepping mechanism for the impaction wheels. An existing three-stage rotating drum impactor was modified, to obtain new midpoint cutoff diameters at 2.5 μm, 1 μm, and 0.1 μm, respectively. For RDI samples collected under ambient air conditions, information on the size-segregation and the spatial uniformity of the deposited particles are key factors for a reliable spectrometric analysis of the RDI deposits. Two aerodynamic particle sizers (APS) were used for the determination of the RDI size fractionation characteristics, using polydisperse laboratory room air as quasi-stable proxy for urban ambient air. This experimental approach was suitable for the scope of this study, but was subject to numerous boundary conditions that limit a general use. Aerodynamic stage penetration midpoint diameters were estimated to be 2.4 and 1.0 μm for the first two RDI stages. Additionally, the spatial uniformity and geometrical size distribution of the deposited aerosol were investigated using micro-focus synchrotron radiation X-ray fluorescence spectrometry (micro-SR-XRF) and transmission electron microscopy (TEM), respectively. The size distribution of the particles found on the TEM samples agreed well with the results from the APS experiments. The RDI deposits showed sufficient uniformity for subsequent spectrometric analysis, but in the 2.5–10 μm size range the particle area density was very low. All of the applied methods confirmed the theoretical cutoff values of the modified RDI and showed that compared to other cascade impactors, the determined stage penetration sharpness was rather broad for the individual impactor stages.
Schlagwörter
Fachgebiet (DDC)
550 - Geowissenschaften
Veranstaltung
Startdatum der Ausstellung
Enddatum der Ausstellung
Startdatum der Konferenz
Enddatum der Konferenz
Datum der letzten Prüfung
ISBN
ISSN
0278-6826
1521-7388
1521-7388
Sprache
Englisch
Während FHNW Zugehörigkeit erstellt
Nein
Zukunftsfelder FHNW
Publikationsstatus
Veröffentlicht
Begutachtung
Peer-Review der ganzen Publikation
Open Access-Status
Closed
Lizenz
Zitation
BUKOWIECKI, Nicolas, Agnes RICHARD, Markus FURGER, Ernest WEINGARTNER, Myriam AGUIRRE, Thomas HUTHWELKER, Peter LIENEMANN, Robert GEHRIG und Urs BALTENSPERGER, 2009. Deposition uniformity and particle size distribution of ambient aerosol collected with a rotating drum impactor. Aerosol Science and Technology. 30 Juni 2009. Bd. 43, Nr. 9, S. 891–901. DOI 10.1080/02786820903002431. Verfügbar unter: https://irf.fhnw.ch/handle/11654/46657