Experimental assessment of the performances of an anisotropic magnetoresistive sensor after exposure to strong magnetic fields
dc.contributor.author | Vergne, Céline | |
dc.contributor.author | Nicolas, Hugo | |
dc.contributor.author | Madec, Morgan | |
dc.contributor.author | Hemm-Ode, Simone | |
dc.contributor.author | Guzman, Raphael | |
dc.contributor.author | Pascal, Joris | |
dc.date.accessioned | 2024-02-08T09:48:53Z | |
dc.date.available | 2024-02-08T09:48:53Z | |
dc.date.issued | 2023 | |
dc.description.abstract | On-chip magnetometers are already integrated within long-term implants such as cardiac implantable electronic devices. They are also good candidates to be integrated within the next generations of brain stimulation electrodes to provide their position and orientation. In all cases, long-term implants are expected to be at least certified as MRI conditional. We investigated the resilience to the exposure to 3 T and 7 T of an anisotropic magnetoresistive sensor integrating a set/reset function. The sensitivity, non-linearity, and offset of a batch of 63 identical sensors were not affected by the exposure. These preliminary results provide new insights on the usability of magnetoresistive sensors for biomedical applications requiring MRI conditionality. | |
dc.event | 2023 IEEE International Magnetic Conference | |
dc.event.end | 2023-05-19 | |
dc.event.start | 2023-05-15 | |
dc.identifier.doi | 10.1109/INTERMAGShortPapers58606.2023.10228438 | |
dc.identifier.uri | https://irf.fhnw.ch/handle/11654/44080 | |
dc.language.iso | en | |
dc.publisher | IEEE | |
dc.relation.ispartof | 2023 IEEE International Magnetic Conference - Short Papers (INTERMAG Short Papers) | |
dc.relation.ispartofseries | INTERMAG Short Papers | |
dc.spatial | Sendai, Japan | |
dc.subject.ddc | 600 - Technik, Medizin, angewandte Wissenschaften | |
dc.title | Experimental assessment of the performances of an anisotropic magnetoresistive sensor after exposure to strong magnetic fields | |
dc.type | 04B - Beitrag Konferenzschrift | |
dspace.entity.type | Publication | |
fhnw.InventedHere | Yes | |
fhnw.ReviewType | Anonymous ex ante peer review of a complete publication | |
fhnw.affiliation.hochschule | Hochschule für Life Sciences FHNW | de_CH |
fhnw.affiliation.institut | Institut für Medizintechnik und Medizininformatik | de_CH |
fhnw.openAccessCategory | Closed | |
fhnw.publicationState | Published | |
relation.isAuthorOfPublication | ec60854b-7fbb-4700-8cce-b587d44145fa | |
relation.isAuthorOfPublication | 1b0b5075-afff-4d8a-954e-e6b6e3eca5ab | |
relation.isAuthorOfPublication | 751f4aee-97bb-4592-91f2-6e3e4623de25 | |
relation.isAuthorOfPublication | 086a20e5-03cc-45e5-95f0-bdee42520e47 | |
relation.isAuthorOfPublication.latestForDiscovery | ec60854b-7fbb-4700-8cce-b587d44145fa |
Dateien
Lizenzbündel
1 - 1 von 1
Kein Vorschaubild vorhanden
- Name:
- license.txt
- Größe:
- 1.36 KB
- Format:
- Item-specific license agreed upon to submission
- Beschreibung: