Application-matched point-of-care 3D printing of functionalized polyetheretherketone (PEEK) composites for patient-specific craniomaxillofacial implants
Lade...
Autor:in (Körperschaft)
Publikationsdatum
2026
Typ der Arbeit
Studiengang
Typ
01A - Beitrag in wissenschaftlicher Zeitschrift
Herausgeber:innen
Herausgeber:in (Körperschaft)
Betreuer:in
Übergeordnetes Werk
3D Printing in Medicine
Themenheft
DOI der Originalpublikation
Link
Zugehörige Forschungsdaten
Reihe / Serie
Reihennummer
Jahrgang / Band
12
Ausgabe / Nummer
1
Seiten / Dauer
Patentnummer
Verlag / Herausgebende Institution
BioMed Central
Verlagsort / Veranstaltungsort
Auflage
Version
Programmiersprache
Abtretungsempfänger:in
Praxispartner:in/Auftraggeber:in
Zusammenfassung
BACKGROUND:
Native polyetheretherketone (PEEK) exhibits limitations in mechanical strength, radiographic visibility, and bioactivity for craniomaxillofacial (CMF) applications. This proof-of-concept study establishes the feasibility of point-of-care (POC) manufacturing for three functionalized PEEK composites for patient-specific CMF implants using a high-temperature material extrusion (MEX) system, with application-specific material selection to overcome these limitations.
METHODS:
Carbon fiber-reinforced PEEK (CFR-PEEK), barium sulfate-filled PEEK (BaSO₄-PEEK), and biphasic calcium phosphate-filled PEEK (BCP-PEEK) were fabricated into patient-specific mandibular reconstruction plates, orbital floor implants, and chin augmentation implants, respectively. Manufacturing success rates, dimensional accuracy via root mean square (RMS) deviation analysis, post-sterilization dimensional stability, and layer adhesion quality were evaluated.
RESULTS:
Fabrication success rates of 100% (CFR-PEEK), 100% (BaSO₄-PEEK), and 85.7% (BCP-PEEK) were achieved. Dimensional accuracy analysis revealed RMS deviations of 0.16-0.29 mm between 3D-printed implants and original designs, within clinically acceptable ranges. Post-sterilization dimensional changes were minimal (RMS 0.05-0.07 mm). Complete layer adhesion was demonstrated across all materials, with no delamination or cracking observed.
CONCLUSION:
These findings establish the manufacturing viability of POC fabrication of application-matched PEEK composites for patient-specific CMF implants, enhancing mechanical, radiographic, and bioactive properties whilst maintaining geometric customization.
Schlagwörter
Fachgebiet (DDC)
Veranstaltung
Startdatum der Ausstellung
Enddatum der Ausstellung
Startdatum der Konferenz
Enddatum der Konferenz
Datum der letzten Prüfung
ISBN
ISSN
2365-6271
Sprache
Englisch
Während FHNW Zugehörigkeit erstellt
Ja
Zukunftsfelder FHNW
Publikationsstatus
Veröffentlicht
Begutachtung
peer-reviewed
Open Access-Status
Gold
Zitation
Oteiza, J. Z., Krieger, Y., Seiler, D., Thieringer, F. M., & Sharma, N. (2026). Application-matched point-of-care 3D printing of functionalized polyetheretherketone (PEEK) composites for patient-specific craniomaxillofacial implants. 3D Printing in Medicine, 12(1). https://doi.org/10.1186/s41205-026-00331-z