Advancing Raman model calibration for perfusion bioprocesses using spiked harvest libraries
Loading...
Authors
Author (Corporation)
Publication date
07.08.2022
Typ of student thesis
Course of study
Collections
Type
01A - Journal article
Editors
Editor (Corporation)
Supervisor
Parent work
Biotechnology Journal
Special issue
DOI of the original publication
Link
Series
Series number
Volume
Issue / Number
Pages / Duration
Patent number
Publisher / Publishing institution
Wiley
Place of publication / Event location
Edition
Version
Programming language
Assignee
Practice partner / Client
Abstract
Background
Raman spectroscopy has gained popularity to monitor multiple process indicators simultaneously in biopharmaceutical processes. However, robust and specific model calibration remains a challenge due to insufficient analyte variability to train the models and high cross-correlation of various media components and artifacts throughout the process.
Main Methods
A systematic Raman calibration workflow for perfusion processes enabling highly specific and fast model calibration was developed. Harvest libraries consisting of frozen harvest samples from multiple CHO cell culture bioreactors collected at different process times were established. Model calibration was subsequently performed in an offline setup using a flow cell by spiking process harvest with glucose, raffinose, galactose, mannose, and fructose.
Major Results
In a screening phase, Raman spectroscopy was proven capable not only to distinguish sugars with similar chemical structures in perfusion harvest but also to quantify them independently in process-relevant concentrations. In a second phase, a robust and highly specific calibration model for simultaneous glucose (root mean square error prediction [RMSEP] = 0.32 g L−1) and raffinose (RMSEP = 0.17 g L−1) real-time monitoring was generated and verified in a third phase during a perfusion process.
Implication
The proposed novel offline calibration workflow allowed proper Raman peak decoupling, reduced calibration time from months down to days, and can be applied to other analytes of interest including lactate, ammonia, amino acids, or product titer.
Graphical Abstract and Lay Summary
Building accurate and robust Raman models for online monitoring of cell culture processes remains a difficult and time-consuming process, particularly for perfusion processes. In this study, the authors developed a novel offline calibration approach based on design-of-experiment spiking and a harvesting library. The Raman spectra of these spiked harvest samples allowed proper peak decoupling and model generation within days instead of weeks or even months. The approach has been successfully applied to monitor various sugars in perfusion bioreactors and other compounds as well as process modes may equally benefit from the described workflow.
Keywords
flowcell, harvestlibrary, model calibration, MVDA, Raman spectroscopy, spiking
Subject (DDC)
500 - Naturwissenschaften
Event
Exhibition start date
Exhibition end date
Conference start date
Conference end date
Date of the last check
ISBN
ISSN
1860-6768
1860-7314
1860-7314
Language
English
Created during FHNW affiliation
Yes
Strategic action fields FHNW
Publication status
Published
Review
Peer review of the complete publication
Open access category
Hybrid
Citation
KOLAR, Jakub, Christoph HERWIG, Jean‐Marc BIELSER, Patrick ROMANN, Daniela TOBLER und Thomas VILLIGER, 2022. Advancing Raman model calibration for perfusion bioprocesses using spiked harvest libraries. Biotechnology Journal. 7 August 2022. DOI 10.1002/biot.202200184. Verfügbar unter: https://doi.org/10.1002/biot.202200184