Management of motion and anatomical variations in charged particle therapy. Past, present, and into the future

dc.accessRightsAnonymous*
dc.contributor.authorPakela, Julia M.
dc.contributor.authorDong, Lei
dc.contributor.authorRucinski, Antoni
dc.contributor.authorZou, Wei
dc.contributor.authorKnopf, Antje
dc.date.accessioned2023-05-11T08:26:54Z
dc.date.available2023-05-11T08:26:54Z
dc.date.issued2022-03-09
dc.description.abstractThe major aim of radiation therapy is to provide curative or palliative treatment to cancerous malignancies while minimizing damage to healthy tissues. Charged particle radiotherapy utilizing carbon ions or protons is uniquely suited for this task due to its ability to achieve highly conformal dose distributions around the tumor volume. For these treatment modalities, uncertainties in the localization of patient anatomy due to inter- and intra-fractional motion present a heightened risk of undesired dose delivery. A diverse range of mitigation strategies have been developed and clinically implemented in various disease sites to monitor and correct for patient motion, but much work remains. This review provides an overview of current clinical practices for inter and intra-fractional motion management in charged particle therapy, including motion control, current imaging and motion tracking modalities, as well as treatment planning and delivery techniques. We also cover progress to date on emerging technologies including particle-based radiography imaging, novel treatment delivery methods such as tumor tracking and FLASH, and artificial intelligence and discuss their potential impact towards improving or increasing the challenge of motion mitigation in charged particle therapy.en_US
dc.identifier.doi10.3389/fonc.2022.806153
dc.identifier.issn2234-943X
dc.identifier.urihttps://irf.fhnw.ch/handle/11654/34929
dc.identifier.urihttps://doi.org/10.26041/fhnw-4851
dc.language.isoenen_US
dc.publisherFrontiersen_US
dc.relation.ispartofFrontiers in Oncologyen_US
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/en_US
dc.subject.ddc600 - Technik, Medizin, angewandte Wissenschaftenen_US
dc.titleManagement of motion and anatomical variations in charged particle therapy. Past, present, and into the futureen_US
dc.type01A - Beitrag in wissenschaftlicher Zeitschrift*
dc.volume12en_US
dspace.entity.typePublication
fhnw.InventedHereNoen_US
fhnw.IsStudentsWorknoen_US
fhnw.ReviewTypeAnonymous ex ante peer review of a complete publicationen_US
fhnw.affiliation.hochschuleHochschule für Life Sciences FHNWde_CH
fhnw.affiliation.institutInstitut für Medizintechnik und Medizininformatikde_CH
fhnw.openAccessCategoryGolden_US
fhnw.publicationStatePublisheden_US
relation.isAuthorOfPublication7c92bfb0-ba14-40c5-8233-6f259dffa6d2
relation.isAuthorOfPublication.latestForDiscovery7c92bfb0-ba14-40c5-8233-6f259dffa6d2
Dateien

Originalbündel

Gerade angezeigt 1 - 1 von 1
Vorschaubild
Name:
fonc-12-806153.pdf
Größe:
642.51 KB
Format:
Adobe Portable Document Format
Beschreibung:

Lizenzbündel

Gerade angezeigt 1 - 1 von 1
Kein Vorschaubild vorhanden
Name:
license.txt
Größe:
1.37 KB
Format:
Item-specific license agreed upon to submission
Beschreibung: