Fronto-orbital advancement with patient-specific 3D-printed implants and robot-guided laser osteotomy: an in vitro accuracy assessment

dc.contributor.authorMaintz, Michaela
dc.contributor.authorDesan, Nora
dc.contributor.authorSharma, Neha
dc.contributor.authorBeinemann, Jörg
dc.contributor.authorBeyer, Michel
dc.contributor.authorSeiler, Daniel
dc.contributor.authorHonigmann, Philipp
dc.contributor.authorSoleman, Jehuda
dc.contributor.authorGuzman, Raphael
dc.contributor.authorCattin, Philippe C.
dc.contributor.authorThieringer, Florian M.
dc.date.accessioned2025-11-07T15:52:23Z
dc.date.issued2024-12-13
dc.description.abstractPurpose: The use of computer-assisted virtual surgical planning (VSP) for craniosynostosis surgery is gaining increasing implementation in the clinics. However, accurately transferring the preoperative planning data to the operating room remains challenging. We introduced and investigated a fully digital workflow to perform fronto-orbital advancement (FOA) surgery using 3D-printed patient-specific implants (PSIs) and cold-ablation robot-guided laser osteotomy. This novel approach eliminates the need for traditional surgical templates while enhancing precision and customization, offering a more streamlined and efficient surgical process. Methods: Computed tomography data of a patient with craniosynostosis were used to digitally reconstruct the skull and to perform VSP of the FOA. In total, six PSIs per skull were 3D-printed with a medical-grade bioresorbable composite using the Arburg Plastic Freeforming technology. The planned osteotomy paths and the screw holes, including their positions and axis angles, were digitally transferred to the cold-ablation robot-guided osteotome interface. The osteotomies were performed on 3D-printed patient skull models. The implants, osteotomy and final FOA results were scanned and compared to the VSP data. Results: The osteotomy deviations for the skulls indicated an overall maximum distance of 1.7 mm, a median deviation of 0.44 mm, and a maximum root mean square (RMS) error of 0.67 mm. The deviation of the point-to-point surface comparison of the FOA with the VSP data resulted in a median accuracy of 1.27 mm. Accessing the orbital cavity with the laser remained challenging. Conclusion: This in vitro study showcases a novel FOA technique by effectively combining robot-guided laser osteotomy with 3D-printed patient-specific implants, eliminating the need for surgical templates and achieving high accuracy in bone cutting and positioning. The workflow holds promise for reducing preoperative planning time and increasing surgical efficiency. Further studies on bone tissue are required to validate the safety and effectiveness of this approach, especially in addressing the challenges of pediatric craniofacial surgery.
dc.identifier.doi10.1007/s11548-024-03298-6
dc.identifier.issn1861-6429
dc.identifier.issn1861-6410
dc.identifier.urihttps://irf.fhnw.ch/handle/11654/53734
dc.identifier.urihttps://doi.org/10.26041/fhnw-14094
dc.issue3
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofInternational Journal of Computer Assisted Radiology and Surgery
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectComputer-aided design
dc.subjectCraniosynostosis
dc.subjectLaser osteotome
dc.subjectPatient-specific implants
dc.subjectPediatrics
dc.subjectRobot-assisted surgery
dc.subject.ddc600 - Technik, Medizin, angewandte Wissenschaften
dc.titleFronto-orbital advancement with patient-specific 3D-printed implants and robot-guided laser osteotomy: an in vitro accuracy assessment
dc.type01A - Beitrag in wissenschaftlicher Zeitschrift
dc.volume20
dspace.entity.typePublication
fhnw.InventedHereYes
fhnw.ReviewTypeAnonymous ex ante peer review of a complete publication
fhnw.affiliation.hochschuleHochschule für Life Sciences FHNWde_CH
fhnw.affiliation.institutInstitut für Medizintechnik und Medizininformatikde_CH
fhnw.openAccessCategoryHybrid
fhnw.pagination513-524
fhnw.publicationStatePublished
fhnw.strategicActionFieldFuture Health
relation.isAuthorOfPublicationab8b66e8-0f66-4375-82db-a31457ecef60
relation.isAuthorOfPublication3e7e21ba-79ae-417a-bfdc-c304bd501226
relation.isAuthorOfPublication.latestForDiscoveryab8b66e8-0f66-4375-82db-a31457ecef60
Dateien

Originalbündel

Gerade angezeigt 1 - 1 von 1
Lade...
Vorschaubild
Name:
s11548-024-03298-6.pdf
Größe:
3.42 MB
Format:
Adobe Portable Document Format

Lizenzbündel

Gerade angezeigt 1 - 1 von 1
Lade...
Vorschaubild
Name:
license.txt
Größe:
2.66 KB
Format:
Item-specific license agreed upon to submission
Beschreibung: