In vitro assessment and comparison of a novel electromagnetic tracking system for stereotactic DBS surgery
Lade...
Autor:in (Körperschaft)
Publikationsdatum
10.04.2025
Typ der Arbeit
Studiengang
Typ
01A - Beitrag in wissenschaftlicher Zeitschrift
Herausgeber:innen
Herausgeber:in (Körperschaft)
Betreuer:in
Übergeordnetes Werk
Annals of Biomedical Engineering
Themenheft
DOI der Originalpublikation
Link
Reihe / Serie
Reihennummer
Jahrgang / Band
53
Ausgabe / Nummer
Seiten / Dauer
1512–1523
Patentnummer
Verlag / Herausgebende Institution
Springer Science and Business Media LLC
Verlagsort / Veranstaltungsort
Auflage
Version
Programmiersprache
Abtretungsempfänger:in
Praxispartner:in/Auftraggeber:in
Zusammenfassung
Real-time guidance for the implantation of deep-brain-stimulation (DBS) electrodes in the context of stereotactic neurosurgery is essential but currently unavailable. Electromagnetic tracking (EMT) systems offer high-accuracy localization of tools in restricted volumes but face compatibility issues with stereotactic procedures due to electromagnetic distortions. This paper aims to evaluate and compare the localization performance (position and orientation) of a novel EMT system, the ManaDBS, specifically designed for stereotactic surgical environments, against the NDI Aurora, a commercially available EMT system. Two studies were conducted to assess the suitability of each EMT system for stereotactic DBS surgery. The first study evaluated performance accuracy within the measurement volume in the presence of two different stereotactic systems (Frame G and Vantage system, Elekta). The second study simulated a DBS surgical theater, performing implantation procedures with each EMT system and evaluating the position accuracy of the EMT sensor. The localization errors of Aurora (0.66 mm and 0.89°) were lower to those of ManaDBS (1.57 mm and 1.01°). However, in the presence of a stereotactic system, Aurora exhibited notable degradation (2.34 mm and 1.03°), whereas ManaDBS remained unaffected. This pattern persisted during simulated implantation in a DBS surgical environment, where nonlinear trajectories with significant error fluctuations along the implantation path were observed with Aurora system. The significant electromagnetic-field distortions render the Aurora system incompatible for stereotactic DBS surgery. However, the ManaDBS system exhibited no impact from these distortions, suggesting its potential suitability for DBS surgery and other potential applications in stereotactic neurosurgery.
Schlagwörter
Deep brain stimulation, Electromagnetic tracking, Interventional guidance, Stereotactic neurosurgery, System assessment
Fachgebiet (DDC)
Veranstaltung
Startdatum der Ausstellung
Enddatum der Ausstellung
Startdatum der Konferenz
Enddatum der Konferenz
Datum der letzten Prüfung
ISBN
ISSN
0090-6964
1573-9686
1573-9686
Sprache
Englisch
Während FHNW Zugehörigkeit erstellt
Ja
Zukunftsfelder FHNW
Publikationsstatus
Veröffentlicht
Begutachtung
Peer-Review der ganzen Publikation
Open Access-Status
Hybrid
Zitation
Vergne, C., Madec, M., Guzman, R., Pascal, J., Taub, E., Bourgeois, F., & Hemm-Ode, S. (2025). In vitro assessment and comparison of a novel electromagnetic tracking system for stereotactic DBS surgery. Annals of Biomedical Engineering, 53, 1512–1523. https://doi.org/10.1007/s10439-025-03728-9