The prebound-effect in detail: real indoor temperatures in basements and measured versus calculated U-values
dc.accessRights | Anonymous | |
dc.audience | Science | |
dc.contributor.author | Hoffmann, Caroline | |
dc.contributor.author | Geissler, Achim | |
dc.date.accessioned | 2017-09-13T07:16:11Z | |
dc.date.available | 2017-09-13T07:16:11Z | |
dc.date.issued | 2017-09-12 | |
dc.description.abstract | This paper focuses on the topics U-values and indoor air temperatures of unheated basements with uninsulated cellar ceilings. Measurement values are compared with calculation procedures suggested by building regulations. Concerning the U-values it is shown that they are typically considered to be higher (i.e. worse) in uninsulated existing constructions than they effectively are. Measured temperatures in seven basements are higher (around 8 K) than a calculation according to regulations would yield. The paper derives suggestions for the adjustment of calculations focused on existing residential buildings. | |
dc.identifier.doi | 10.1016/j.egypro.2017.07.301 | |
dc.identifier.issn | 1876-6102 | |
dc.identifier.uri | http://hdl.handle.net/11654/25446 | |
dc.identifier.uri | https://doi.org/10.26041/fhnw-1154 | |
dc.language.iso | en_US | |
dc.publisher | Elsevier | en_US |
dc.relation.ispartof | Energy Procedia | en_US |
dc.subject | U-value | en_US |
dc.subject | basement temperature | en_US |
dc.subject | measurement | en_US |
dc.subject.ddc | 690 - Hausbau, Bauhandwerk | de |
dc.subject.ddc | 600 - Technik | de |
dc.title | The prebound-effect in detail: real indoor temperatures in basements and measured versus calculated U-values | |
dc.type | 01A - Beitrag in wissenschaftlicher Zeitschrift | |
dc.volume | 122 | |
dspace.entity.type | Publication | |
fhnw.InventedHere | Yes | |
fhnw.IsStudentsWork | no | |
fhnw.PublishedSwitzerland | No | |
fhnw.ReviewType | Anonymous ex ante peer review of a complete publication | |
fhnw.affiliation.hochschule | Hochschule für Architektur, Bau und Geomatik FHNW | de_CH |
fhnw.affiliation.institut | Institut Nachhaltigkeit und Energie am Bau | de_CH |
fhnw.pagination | 32-37 | |
fhnw.publicationOnline | Ja | |
fhnw.publicationState | Published | |
relation.isAuthorOfPublication | 87a78247-cb0d-4a35-98e3-413881d5f420 | |
relation.isAuthorOfPublication | dff0779c-e35e-4e1d-97ed-b41a2b6ae1ac | |
relation.isAuthorOfPublication.latestForDiscovery | 87a78247-cb0d-4a35-98e3-413881d5f420 |
Dateien
Originalbündel
1 - 1 von 1
- Name:
- Final_Version_Hoffmann_Geissler_Energy_Procedia_20170912.pdf
- Größe:
- 778.74 KB
- Format:
- Adobe Portable Document Format
- Beschreibung: