The prebound-effect in detail: real indoor temperatures in basements and measured versus calculated U-values
| dc.accessRights | Anonymous | |
| dc.audience | Science | |
| dc.contributor.author | Hoffmann, Caroline | |
| dc.contributor.author | Geissler, Achim | |
| dc.date.accessioned | 2017-09-13T07:16:11Z | |
| dc.date.available | 2017-09-13T07:16:11Z | |
| dc.date.issued | 2017-09-12 | |
| dc.description.abstract | This paper focuses on the topics U-values and indoor air temperatures of unheated basements with uninsulated cellar ceilings. Measurement values are compared with calculation procedures suggested by building regulations. Concerning the U-values it is shown that they are typically considered to be higher (i.e. worse) in uninsulated existing constructions than they effectively are. Measured temperatures in seven basements are higher (around 8 K) than a calculation according to regulations would yield. The paper derives suggestions for the adjustment of calculations focused on existing residential buildings. | |
| dc.identifier.doi | 10.1016/j.egypro.2017.07.301 | |
| dc.identifier.issn | 1876-6102 | |
| dc.identifier.uri | http://hdl.handle.net/11654/25446 | |
| dc.identifier.uri | https://doi.org/10.26041/fhnw-1154 | |
| dc.language.iso | en_US | |
| dc.publisher | Elsevier | en_US |
| dc.relation | Offene Fragen beim Einsatz der SIA 380/1 als Prognoseinstrument bei Bestandsgebäuden (Wohnbauten), 2015-05-01 | |
| dc.relation.ispartof | Energy Procedia | en_US |
| dc.subject | U-value | en_US |
| dc.subject | basement temperature | en_US |
| dc.subject | measurement | en_US |
| dc.subject.ddc | 690 - Hausbau, Bauhandwerk | de |
| dc.subject.ddc | 600 - Technik | de |
| dc.title | The prebound-effect in detail: real indoor temperatures in basements and measured versus calculated U-values | |
| dc.type | 01A - Beitrag in wissenschaftlicher Zeitschrift | |
| dc.volume | 122 | |
| dspace.entity.type | Publication | |
| fhnw.InventedHere | Yes | |
| fhnw.IsStudentsWork | no | |
| fhnw.PublishedSwitzerland | No | |
| fhnw.ReviewType | Anonymous ex ante peer review of a complete publication | |
| fhnw.affiliation.hochschule | Hochschule für Architektur, Bau und Geomatik FHNW | de_CH |
| fhnw.affiliation.institut | Institut Nachhaltigkeit und Energie am Bau | de_CH |
| fhnw.pagination | 32-37 | |
| fhnw.publicationOnline | Ja | |
| fhnw.publicationState | Published | |
| relation.isAuthorOfPublication | 87a78247-cb0d-4a35-98e3-413881d5f420 | |
| relation.isAuthorOfPublication | dff0779c-e35e-4e1d-97ed-b41a2b6ae1ac | |
| relation.isAuthorOfPublication.latestForDiscovery | 87a78247-cb0d-4a35-98e3-413881d5f420 | |
| relation.isProjectOfPublication | 4226eb9e-8f3f-4984-a9d7-90c8aee0d611 | |
| relation.isProjectOfPublication.latestForDiscovery | 4226eb9e-8f3f-4984-a9d7-90c8aee0d611 |
Dateien
Originalbündel
1 - 1 von 1
Lade...
- Name:
- Final_Version_Hoffmann_Geissler_Energy_Procedia_20170912.pdf
- Größe:
- 778.74 KB
- Format:
- Adobe Portable Document Format
- Beschreibung: