dc.description.abstract | A thorough building refurbishment generally includes window replacement and thermal insulation of the opaque building envelope. However, quite often only a window replacement is done and the building envelope is left uninsulated. This could lead to mould problems, because of the reduced air change. A possible solution can be the integration of passive window ventilation openings (PWVO). This paper deals with two questions: Firstly, can PWVO guarantee the necessary ventilation rate to avoid moisture damage? Secondly, how do PWVO compare to a ventilation system with heat recovery in terms of heating demand? | |
dc.event | 11th Conference on Advanced Building Skins 2016 | |
dc.event.end | 2016-10-11 | |
dc.event.start | 2016-10-10 | |
dc.identifier.uri | http://hdl.handle.net/11654/23417 | |
dc.identifier.uri | https://doi.org/10.26041/fhnw-784 | |
dc.language.iso | en | |
dc.publisher | Advanced Building Skins | |
dc.relation.ispartof | Advanced Building Skins | |
dc.spatial | Bern | |
dc.subject | transient thermal simulations | en_US |
dc.subject | passive window ventilation openings | en_US |
dc.subject | mould | en_US |
dc.subject.ddc | 600 - Technik | de |
dc.subject.ddc | 624 - Ingenieurbau und Umwelttechnik | de |
dc.subject.ddc | 690 - Hausbau, Bauhandwerk | de |
dc.title | Passive window ventilation openings for building refurbishment | |
dc.type | 04B - Beitrag Konferenzschrift | |
dspace.entity.type | Publication | |
fhnw.InventedHere | Yes | |
fhnw.IsStudentsWork | no | |
fhnw.PublishedSwitzerland | Yes | |
fhnw.ReviewType | Anonymous ex ante peer review of a complete publication | |
fhnw.affiliation.hochschule | Hochschule für Architektur, Bau und Geomatik FHNW | de_CH |
fhnw.affiliation.institut | Institut Nachhaltigkeit und Energie am Bau | de_CH |
fhnw.pagination | 203-212 | |
fhnw.publicationState | Published | |
relation.isAuthorOfPublication | 87a78247-cb0d-4a35-98e3-413881d5f420 | |
relation.isAuthorOfPublication | dff0779c-e35e-4e1d-97ed-b41a2b6ae1ac | |
relation.isAuthorOfPublication.latestForDiscovery | 87a78247-cb0d-4a35-98e3-413881d5f420 |
Dateien
Originalbündel
1 - 1 von 1
- Name:
- PWVO_ABS_Bern.pdf
- Größe:
- 669.32 KB
- Format:
- Adobe Portable Document Format
- Beschreibung:
Lizenzbündel
1 - 1 von 1
Kein Vorschaubild vorhanden
- Name:
- license.txt
- Größe:
- 2.94 KB
- Format:
- Item-specific license agreed upon to submission
- Beschreibung: