Intercomparison study of six HTDMAs. results and recommendations

dc.contributor.authorDuplissy, Jonathan
dc.contributor.authorGysel, Martin
dc.contributor.authorSjogren, S.
dc.contributor.authorMeyer, Nickolas
dc.contributor.authorGood, Nicholas
dc.contributor.authorKammermann, Lukas
dc.contributor.authorMichaud, Vincent
dc.contributor.authorWeigel, Ralf
dc.contributor.authorMartins dos Santos, Sebastiao
dc.contributor.authorGruening, Carsten
dc.contributor.authorVillani, P.
dc.contributor.authorLaj, Paolo
dc.contributor.authorSellegri, Karine
dc.contributor.authorMetzger, Axel
dc.contributor.authorMcFiggans, Gordon B.
dc.contributor.authorWehrle, Günther
dc.contributor.authorRichter, René
dc.contributor.authorDommen, Josef
dc.contributor.authorRistovski, Zoran
dc.contributor.authorBaltensperger, Urs
dc.contributor.authorWeingartner, Ernest
dc.date.accessioned2024-08-13T13:33:50Z
dc.date.available2024-08-13T13:33:50Z
dc.date.issued2009-07-24
dc.description.abstractWe report on an intercomparison of six different hygroscopicity tandem differential mobility analysers HTDMAs). These HTDMAs are used worldwide in laboratory experiments and field campaigns to measure the water uptake of aerosol particles and have never been intercompared. After an investigation of the different design of the instruments with their advantages and inconveniencies, the methods for calibration, validation and data analysis are presented. Measurements of nebulised ammonium sulphate as well as of secondary organic aerosol generated from a smog chamber were performed. Agreement and discrepancies between the instruments and to the theory are discussed, and final recommendations for a standard instrument are given, as a benchmark for laboratory or field experiments to ensure a high quality of HTDMA data.
dc.identifier.issn1867-8548
dc.identifier.issn1867-1381
dc.identifier.urihttps://irf.fhnw.ch/handle/11654/46663
dc.identifier.urihttps://doi.org/10.26041/fhnw-9715
dc.issue2
dc.language.isoen
dc.publisherCopernicus
dc.relation.ispartofAtmospheric Measurement Techniques
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.spatialGöttingen
dc.subject.ddc550 - Geowissenschaften
dc.titleIntercomparison study of six HTDMAs. results and recommendations
dc.type01A - Beitrag in wissenschaftlicher Zeitschrift
dc.volume2
dspace.entity.typePublication
fhnw.InventedHereNo
fhnw.ReviewTypeAnonymous ex ante peer review of a complete publication
fhnw.affiliation.hochschuleHochschule für Technik und Umwelt FHNWde_CH
fhnw.affiliation.institutlnstitut für Sensorik und Elektronikde_CH
fhnw.openAccessCategoryGold
fhnw.pagination363-378
fhnw.publicationStatePublished
relation.isAuthorOfPublication54997bb8-cf4a-4120-b0c7-f8e731e8eea1
relation.isAuthorOfPublication05dd9a19-7a24-4325-805a-2d121483b168
relation.isAuthorOfPublication.latestForDiscovery05dd9a19-7a24-4325-805a-2d121483b168
Dateien

Originalbündel

Gerade angezeigt 1 - 1 von 1
Vorschaubild
Name:
amt-2-363-2009.pdf
Größe:
669.16 KB
Format:
Adobe Portable Document Format

Lizenzbündel

Gerade angezeigt 1 - 1 von 1
Kein Vorschaubild vorhanden
Name:
license.txt
Größe:
2.66 KB
Format:
Item-specific license agreed upon to submission
Beschreibung: