dc.description.abstractMultifamily dwellings and office buildings with a square and a stretched footprint with up to 40 floors are considered for a net zero energy balance. A wide range of parameters is investigated in regard to their impact on the zero energy balance. The main results gained by the simulation based research described above can be summarized as follows: Only the HVAC zero balance can be achieved for up to 40 floors for all variants studied but one. The five main parameters in regard to achieving a HVAC or TE zero energy balance are, efficient electric devices and lighting, low heat demand, the type of heating system, the actually available area for PV and the overall efficiency of the PV-System. The results show that a net zero energy balance for HVAC only or for total energy can be achieved for large multifamily dwellings and office buildings of up to 40 floors. To this end, however, apart from a well-insulated building envelope, electronic devices, lighting and PV systems with a very high efficiency are necessary. With further improvements in the efficiency of devices, lighting and PV-systems, reaching the "zero" will become easier.
dc.event11th Conference on Advanced Building Skins 2016
dc.event.end2016-10-11
dc.event.start2016-10-10
dc.identifier.urihttp://hdl.handle.net/11654/23418
dc.identifier.urihttps://doi.org/10.26041/fhnw-785
dc.language.isoen
dc.publisherAdvanced Building Skins
dc.relation.ispartofAdvanced Building Skins
dc.spatialBern
dc.subjectNet zero energy building
dc.subjectPV-facade
dc.subjecthigh-rise building
dc.subjectself-consumption
dc.subjectnet zero energy balance
dc.titleNet zero energy balance for high-rise buildings
dc.type04B - Beitrag Konferenzschrift
dspace.entity.typePublication
fhnw.InventedHereYes
fhnw.IsStudentsWorkno
fhnw.PublishedSwitzerlandYes
fhnw.ReviewTypeAnonymous ex ante peer review of an abstract
fhnw.affiliation.hochschuleHochschule für Architektur, Bau und Geomatikde_CH
fhnw.affiliation.institutInstitut Nachhaltigkeit und Energie am Baude_CH
fhnw.pagination53-61
fhnw.publicationStatePublished
relation.isAuthorOfPublication29755986-0864-4ca5-92db-f08f187d444b
relation.isAuthorOfPublicationdff0779c-e35e-4e1d-97ed-b41a2b6ae1ac
relation.isAuthorOfPublication.latestForDiscovery29755986-0864-4ca5-92db-f08f187d444b
Dateien
Originalbündel
Gerade angezeigt 1 - 1 von 1
Lade...
Vorschaubild
Name:
2016 ABS_A3_3_Hall_Geissler_NZEB_high-rise buildings.pdf
Größe:
828.36 KB
Format:
Adobe Portable Document Format
Beschreibung:
Lizenzbündel
Gerade angezeigt 1 - 1 von 1
Lade...
Vorschaubild
Name:
license.txt
Größe:
2.94 KB
Format:
Item-specific license agreed upon to submission
Beschreibung: