Magnetic field interactions of smartwatches and portable electronic devices with CIEDs. Did we open a Pandora’s box?
dc.accessRights | Anonymous | * |
dc.contributor.author | Badertscher, Patrick | |
dc.contributor.author | Vergne, Céline | |
dc.contributor.author | Féry, Corentin | |
dc.contributor.author | Mannhart, Diego | |
dc.contributor.author | Quirin, Thomas | |
dc.contributor.author | Osswald, Stefan | |
dc.contributor.author | Kühne, Michael | |
dc.contributor.author | Sticherling, Christian | |
dc.contributor.author | Knecht, Stefan | |
dc.contributor.author | Pascal, Joris | |
dc.date.accessioned | 2023-02-09T06:50:02Z | |
dc.date.available | 2023-02-09T06:50:02Z | |
dc.date.issued | 2022-12 | |
dc.description.abstract | Magnetic interaction of portable electronic devices (PEDs), such as state-of-the art mobile phones, with cardiovascular implantable electronic devices (CIEDs) has been reported. The aim of the study was to quantify the magnetic fields of latest generation smartwatches and other PEDs and to evaluate and predict their risk of CIED interactions. | en_US |
dc.identifier.doi | 10.1016/j.ijcha.2022.101122 | |
dc.identifier.issn | 2352-9067 | |
dc.identifier.uri | https://irf.fhnw.ch/handle/11654/34541 | |
dc.identifier.uri | https://doi.org/10.26041/fhnw-4606 | |
dc.language.iso | en | en_US |
dc.publisher | Elsevier | en_US |
dc.relation.ispartof | International Journal of Cardiology Heart & Vasculature | en_US |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | en_US |
dc.spatial | Amsterdam | en_US |
dc.subject | CIED | en_US |
dc.subject | Magnetic field | en_US |
dc.subject | Interaction | en_US |
dc.subject | Portable electronic devices | en_US |
dc.subject | Smartwatch | en_US |
dc.subject | Apple Watch | en_US |
dc.subject.ddc | 600 - Technik, Medizin, angewandte Wissenschaften | en_US |
dc.title | Magnetic field interactions of smartwatches and portable electronic devices with CIEDs. Did we open a Pandora’s box? | en_US |
dc.type | 01A - Beitrag in wissenschaftlicher Zeitschrift | |
dc.volume | 43 | en_US |
dspace.entity.type | Publication | |
fhnw.InventedHere | Yes | en_US |
fhnw.IsStudentsWork | no | en_US |
fhnw.ReviewType | Anonymous ex ante peer review of a complete publication | en_US |
fhnw.affiliation.hochschule | Hochschule für Life Sciences FHNW | de_CH |
fhnw.affiliation.institut | Institut für Medizintechnik und Medizininformatik | de_CH |
fhnw.openAccessCategory | Gold | en_US |
fhnw.pagination | 1-6 | en_US |
fhnw.publicationState | Published | en_US |
relation.isAuthorOfPublication | cdc41e45-6176-48b9-81c8-af44a954ba31 | |
relation.isAuthorOfPublication | ec60854b-7fbb-4700-8cce-b587d44145fa | |
relation.isAuthorOfPublication | bf0d87e2-922b-4809-b474-65a8519eb134 | |
relation.isAuthorOfPublication | 3c9ac29a-5fb3-4d0f-9b8c-44cacb029c69 | |
relation.isAuthorOfPublication | 086a20e5-03cc-45e5-95f0-bdee42520e47 | |
relation.isAuthorOfPublication.latestForDiscovery | 086a20e5-03cc-45e5-95f0-bdee42520e47 |
Dateien
Originalbündel
1 - 1 von 1
- Name:
- 1-s2.0-S2352906722001713-main.pdf
- Größe:
- 2.62 MB
- Format:
- Adobe Portable Document Format
- Beschreibung:
Lizenzbündel
1 - 1 von 1
Kein Vorschaubild vorhanden
- Name:
- license.txt
- Größe:
- 1.37 KB
- Format:
- Item-specific license agreed upon to submission
- Beschreibung: