Flow-through cross-polarized imaging as a new tool to overcome the analytical sensitivity challenges of a low-dose crystalline compound in a lipid matrix
Vorschaubild nicht verfügbar
Autor:innen
Autor:in (Körperschaft)
Publikationsdatum
10.11.2015
Typ der Arbeit
Studiengang
Sammlung
Typ
01A - Beitrag in wissenschaftlicher Zeitschrift
Herausgeber:innen
Herausgeber:in (Körperschaft)
Betreuer:in
Übergeordnetes Werk
Journal of Pharmaceutical and Biomedical Analysis
Themenheft
DOI der Originalpublikation
Link
Reihe / Serie
Reihennummer
Jahrgang / Band
115
Ausgabe / Nummer
Seiten / Dauer
20-30
Patentnummer
Verlag / Herausgebende Institution
Elsevier
Verlagsort / Veranstaltungsort
Auflage
Version
Programmiersprache
Abtretungsempfänger:in
Praxispartner:in/Auftraggeber:in
Zusammenfassung
Assessing the physical state of a low-dose active compound in a solid lipid or polymer matrix is analytically challenging, especially if the matrix exhibits some crystallinity. The aim of this study was first to compare the ability of current methods to detect the presence of a crystalline model compound in lipid matrices. Subsequently, a new technique was introduced and evaluated because of sensitivity issues that were encountered with current methods. The new technique is a flow-through version of cross-polarized imaging in transmission mode. The tested lipid-based solid dispersions (SDs) consisted of β-carotene (BC) as a model compound, and of Gelucire 50/13 or Geleol mono- and diglycerides as lipid matrices. The solid dispersions were analyzed by (hyper) differential scanning calorimetry (DSC), X-ray powder diffraction (XRPD), and microscopic techniques including atomic force microscopy (AFM). DSC and XRPD could analyze crystalline BC at concentrations as low as 3% (w/w) in the formulations. However, with microscopic techniques crystalline particles were detected at significantly lower concentrations of even 0.5% (w/w) BC. A flow-through cross-polarized imaging technique was introduced that combines the advantage of analyzing a larger sample size with high sensitivity of microscopy. Crystals were detected easily in samples containing even less than 0.2% (w/w) BC. Moreover, the new tool enabled approximation of the kinetic BC solubility in the crystalline lipid matrices. As a conclusion, the flow-through cross-polarized imaging technique has the potential to become an indispensable tool for characterizing low-dose crystalline compounds in a lipid or polymer matrix of solid dispersions.
Schlagwörter
Analytical tools, Crystalline active compound, Flow-through cross-polarized imaging, Sampling issues, Sensitivity limits, Solid lipid formulations
Fachgebiet (DDC)
Veranstaltung
Startdatum der Ausstellung
Enddatum der Ausstellung
Startdatum der Konferenz
Enddatum der Konferenz
Datum der letzten Prüfung
ISBN
ISSN
0731-7085
1873-264X
1873-264X
Sprache
Englisch
Während FHNW Zugehörigkeit erstellt
Ja
Zukunftsfelder FHNW
Publikationsstatus
Veröffentlicht
Begutachtung
Peer-Review der ganzen Publikation
Open Access-Status
Lizenz
Zitation
ADLER, Camille, Monica SCHÖNENBERGER, Alexandra TELEKI, Bruno LEUENBERGER und Martin KUENTZ, 2015. Flow-through cross-polarized imaging as a new tool to overcome the analytical sensitivity challenges of a low-dose crystalline compound in a lipid matrix. Journal of Pharmaceutical and Biomedical Analysis. 10 November 2015. Bd. 115, S. 20–30. DOI 10.1016/j.jpba.2015.06.033. Verfügbar unter: http://hdl.handle.net/11654/11957