Institut für Medizintechnik und Medizininformatik

Dauerhafte URI für die Sammlunghttps://irf.fhnw.ch/handle/11654/23

Listen

Ergebnisse nach Hochschule und Institut

Gerade angezeigt 1 - 5 von 5
  • Publikation
    Towards a new generation of electromagnetic navigation system for deep brain stimulation
    (European Society for Stereotactic and Functional Neurosurgery, 2023) Vergne, Céline; Morgan, Madec; Guzmann, Raphael; Pascal, Joris; Hemm-Ode, Simone
    06 - Präsentation
  • Publikation
    Experimental assessment of the performances of an anisotropic magnetoresistive sensor after exposure to strong magnetic fields
    (IEEE, 2023) Vergne, Céline; Nicolas, Hugo; Madec, Morgan; Hemm-Ode, Simone; Guzman, Raphael; Pascal, Joris
    On-chip magnetometers are already integrated within long-term implants such as cardiac implantable electronic devices. They are also good candidates to be integrated within the next generations of brain stimulation electrodes to provide their position and orientation. In all cases, long-term implants are expected to be at least certified as MRI conditional. We investigated the resilience to the exposure to 3 T and 7 T of an anisotropic magnetoresistive sensor integrating a set/reset function. The sensitivity, non-linearity, and offset of a batch of 63 identical sensors were not affected by the exposure. These preliminary results provide new insights on the usability of magnetoresistive sensors for biomedical applications requiring MRI conditionality.
    04B - Beitrag Konferenzschrift
  • Vorschaubild
    Publikation
    Test-re-test reliability and dynamics of the Fukuda–Unterberger stepping test
    (Frontiers Research Foundation, 29.03.2023) Hemm-Ode, Simone; Baumann, Denise; Duarte da Costa, Vasco; Tarnutzer, Alexander Andrea
    The Fukuda-stepping-test (FST), i.e., repetitive walking on the spot while blindfolded, has been proposed as a means to assess the integrity of the vestibular pathways. While its sensitivity to detect abnormalities in patients is limited, it may be useful in studying the physiology of the subjective-straight-ahead (SSA). Considering reported systematic shifts in SSA in humans, we hypothesize that such asymmetries arise from individual differences in the orientation/configuration of the macular organs and in central processing of vestibular input. We hypothesize that such asymmetries are stable over time in individual subjects. Alternatively, such asymmetries may arise from random noise in the sensory/motor systems involved, demonstrating low reproducibility over time. Materials and methods: Twenty-four subjects walked on the spot over 60 s while blindfolded. Using an inertial measurement unit (IMU) placed at the chest, angular deviations were recorded and compared to manually-measured final positions. Both static (direction, magnitude) and dynamic (time-to-onset of deviation, pattern of deviations) parameters were retrieved from the yaw slopes. Significant deviations were found in 15/24 participants for the manual measurements (leftwards = 8; rightwards = 7), whereas when using the IMU-sensor 13/24 participants showed significant shifts (leftwards = 9; rightwards = 4). There was a high correlation (0.98) between manually measured rotation angles (average absolute deviations = 58.0 deg ± 48.6 deg; intra-individual variability = 39 deg ± 24 deg) and sensor-based yaw slopes (1.00 deg/s ± 0.88 deg/s; 0.67 deg/s ± 0.41 deg/s). Relevant yaw deviation was detected 22.1 s ± 12.3 s (range = 5.6 s-59.2 s) after the onset of marching (no relevant yaw-deviation in 15/139 measurements), showing a mostly linear behavior over time. Conclusion: We observed significant inter-individual variability in task performance in the FST, reproducing findings from previous studies. With test-re-test reliability being moderate only, but at the same time observing a preference in the side of shifts in most trials and subjects, we conclude that likely both individually varying estimates of straight-ahead and random noise contribute to the pattern of angular deviations observed. Using an IMU-sensory based approach, additional dynamic parameters could be retrieved, emphasizing the value of such a quantitative approach over manual measurements. Such an approach may provide useful additional information to distinguish patients from healthy controls.
    01A - Beitrag in wissenschaftlicher Zeitschrift
  • Vorschaubild
    Publikation
    How sample size impacts probabilistic stimulation maps in deep brain stimulation
    (MDPI, 03.05.2023) Nordin, Teresa; Blomstedt, Patric; Hemm-Ode, Simone; Wårdell, Karin
    Probabilistic stimulation maps of deep brain stimulation (DBS) effect based on voxel-wise statistics (p-maps) have increased in literature over the last decade. These p-maps require correction for Type-1 errors due to multiple testing based on the same data. Some analyses do not reach overall significance, and this study aims to evaluate the impact of sample size on p-map computation. A dataset of 61 essential tremor patients treated with DBS was used for the investigation. Each patient contributed with four stimulation settings, one for each contact. From the dataset, 5 to 61 patients were randomly sampled with replacement for computation of p-maps and extraction of high- and low-improvement volumes. For each sample size, the process was iterated 20 times with new samples generating in total 1140 maps. The overall p-value corrected for multiple comparisons, significance volumes, and dice coefficients (DC) of the volumes within each sample size were evaluated. With less than 30 patients (120 simulations) in the sample, the variation in overall significance was larger and the median significance volumes increased with sample size. Above 120 simulations, the trends stabilize but present some variations in cluster location, with a highest median DC of 0.73 for n = 57. The variation in location was mainly related to the region between the high- and low-improvement clusters. In conclusion, p-maps created with small sample sizes should be evaluated with caution, and above 120 simulations in single-center studies are probably required for stable results.
    01A - Beitrag in wissenschaftlicher Zeitschrift
  • Publikation
    Low-field electromagnetic tracking using 3-D magnetometer for assisted surgery
    (IEEE, 02/2023) Vergne, Céline; Féry, Corentin; Quirin, Thomas; Nicolas, Hugo; Madec, Morgan; Hemm-Ode, Simone; Pascal, Joris
    01A - Beitrag in wissenschaftlicher Zeitschrift