Institut Nachhaltigkeit und Energie am Bau
Dauerhafte URI für die Sammlunghttps://irf.fhnw.ch/handle/11654/10
Listen
4 Ergebnisse
Ergebnisse nach Hochschule und Institut
Publikation Passive window ventilation openings in every-day use(Advanced Building Skins, 10/2019) Hoffmann, Caroline; Geissler, Achim; Huber, Heinrich; Hauri, ClaudiaIn Switzerland, 70 % of building refurbishments are realised in stages. When only a window replacement is done, the new airtight windows can lead to a reduced infiltration air exchange and subsequently there may be moisture issues, e.g. mould. The integration of passive window ventilation openings (PWVO) with additional exhaust fans in the kitchen and bathroom(s) can ensure a user-independent basic air change rate. PWVO can be defined as small air inlets integrated in or near the window frame. These inlets enable a basic air exchange due to the pressure difference between inside and outside. This project is focused on how well buildings with PWVO work in real life.04B - Beitrag KonferenzschriftPublikation Beleuchtungen mit nicht-visuellen Eigenschaften im Praxistest(Hogrefe, 11/2019) Hoffmann, CarolineEine Lichtversorgung, die tagsüber den Verlauf des Tageslichts nachbildet, kann Schlaflosigkeit in der Nacht mildern. Davon profitieren vor allem ältere Menschen, die in Pflegeheimen leben und wenig direkten Zugang zum Tageslicht haben. In einem Forschungsprojekt hat die Fachhochschule Nordwestschweiz fünf Beleuchtungssysteme in den Räumen der Universitären Altersmedizin FELIX PLATTER untersucht.01A - Beitrag in wissenschaftlicher ZeitschriftPublikation Luminaires and their non-visual characteristics - comparison of five electric lighting systems in a university centre for geriatrics and rehabilitation(VIA-Verlag, 02.11.2017) Hoffmann, Caroline; Ritter, JoachimThe paper describes findings resulting from a research project comparing five different lighting systems which claim to enhance non-visual responses.04B - Beitrag KonferenzschriftPublikation Luminaires with Non-Visual Characteristics - Photometric Measurements and Comparison of Five Electric Lighting Systems(Karger, 07/2017) Hoffmann, CarolineEs werden fünf Beleuchtungslösungen mit nicht-visueller Wirkung miteinander verglichen. Die Beleuchtungen waren im Felix Platter-Spital in Basel installiert. Der Vergleich wird über lichttechnische Messungen und Befragungen durchgeführt. Der Kurzartikel konzentriert sich auf den Vergleich von zwei lichttechnischen Bestimmungsmethoden zur nicht-visuellen Wirkung von Licht auf den Menschen (Wirkungsfaktor für die Melatoninsuppression in der Nacht und Effektive Bestrahlungsstärke auf die Photorezeptoren des menschlichen Auges)..01A - Beitrag in wissenschaftlicher Zeitschrift