de Wild, Michael
Lade...
E-Mail-Adresse
Geburtsdatum
Projekt
Organisationseinheiten
Berufsbeschreibung
Nachname
de Wild
Vorname
Michael
Name
de Wild, Michael
76 Ergebnisse
Suchergebnisse
Gerade angezeigt 1 - 10 von 76
- PublikationGeometric cuts by an autonomous laser osteotome increase stability in mandibular reconstruction with free fibula grafts. A cadaver study(Elsevier, 2024) Gottsauner, Maximilian; Morawska, Marta M.; Tempel, Simon; Müller-Gerbl, Magdalena; Dalcanale, Federico; de Wild, Michael; Ettl, Tobias [in: Journal of Oral and Maxillofacial Surgery]01A - Beitrag in wissenschaftlicher Zeitschrift
- PublikationGeometric cuts by an autonomous laser osteotome increase stability in mandibular reconstruction with free fibula grafts. A cadaver study(Elsevier, 2024) Gottsauner, Maximilian; Morawska, Marta M.; Tempel, Simon; Müller-Gerbl, Magdalena; Dalcanale, Federico; de Wild, Michael; Ettl, Tobias [in: Journal of Oral and Maxillofacial Surgery]Background Nonunion and plate exposure represent a major complication after mandibular reconstruction with free fibula flaps. These drawbacks may be resolved by geometric osteotomies increasing intersegmental bone contact area and stability. Purpose The aim of this study was to compare intersegmental bone contact and stability of geometric osteotomies to straight osteotomies in mandibular reconstructions with free fibula grafts performed by robot-guided erbium-doped yttrium aluminum garnet laser osteotomy.01A - Beitrag in wissenschaftlicher Zeitschrift
- PublikationParameter optimization in a finite element mandibular fracture fixation model using the design of experiments approach(Elsevier, 08/2023) Maintz, Michaela; Msallem, Bilal; de Wild, Michael; Seiler, Daniel; Herrmann, Sven; Feiler, Stefanie; Sharma, Neha; Dalcanale, Federico; Cattin, Philippe; Thieringer, Florian Markus [in: Journal of the Mechanical Behavior of Biomedical Materials]01A - Beitrag in wissenschaftlicher Zeitschrift
- PublikationDevelopment of models for additively manufactured actuators using compliant Wren mechanism(Elsevier, 11/2021) Lennart, Rubbert; Schuler, Felix; Gayral, Thibault; de Wild, Michael; Renaud, Pierre [in: Precision Engineering]Compliant Wren mechanisms (CWM) constitute specific compliant structures of particular interest. Derived from Wren mechanisms, they can exhibit a large variety of motions, from quasi translation to quasi rotation. In this paper, the development of models for the analysis and synthesis of CWM is considered. A kinematic model is introduced first to assess all possible motions when used as an actuator. Then the static model and stress expressions are derived to help their design. These derivations are achieved for two types of geometries, corresponding to the geometries of interest. CWM are filigree structures, whose manufacturing is difficult to consider without additive manufacturing. A specific work on their production using selective laser melting (SLM) is then achieved to ensure the reliability of their production. As a proof of concept, a pneumatically actuated component is then developed and tested. It is composed of two CWM of different geometries. It offers the possibility to obtain translation and rotation using a single pressure input. The developed models are investigated using finite element models and experiments using additively manufactured structures.01A - Beitrag in wissenschaftlicher Zeitschrift
- PublikationCaP bone‐like coating for fast osseointegration of dental implants(Wiley, 05.10.2020) Dalcanale, Federico; Bitiqi, Hekuran; de Wild, Michael [in: Clinical Oral Implants Research]01A - Beitrag in wissenschaftlicher Zeitschrift
- PublikationSmart 4D-printed implants and instruments(De Gruyter, 09/2020) de Wild, Michael; Schuler, Felix [in: Current Directions in Biomedical Engineering]Selective laser melting (SLM) was used to manufacture smart programmed structures with customized properties made of biocompatible NiTi shape-memory alloy. A series of helixes was produced with systematically varied SLM process parameters Laser Exposure Time and Laser Power in order to specifically change the thermo-mechanical material properties of the 3D-structures. This innovation opens up the possibility to adjust the NiTi phase transformation temperature during the manufacturing process. This controllable property determines which of the two crystallographic phases martensite or austenite is present at a certain operating temperature and allows the mechanical properties to be adjusted: martensitic devices are soft and pseudo-plastic due to the shape-memory effect, whereas austenitic structures are pseudo-elastic. In a further step, the SLM process parameters were locally varied within 4D-printed twin-helixes. As a result, the phases, respectively the mechanical properties of a single component were adjusted at different locations. The ratio of elastic to plastic deformation and the spring constant of the helix can be locally controlled. This allows, for example, the spatio-temporal programming of 3D-printed surgical instruments or implants that are stimuli-responsive.01A - Beitrag in wissenschaftlicher Zeitschrift
- PublikationThree anchor concepts for rotator cuff repair in standardized physiological and osteoporotic bone: a biomechanical study(Elsevier, 06.10.2019) de Wild, Michael; Dietschy, Alain; Claudio, Rosso; Rosso, Claudio [in: Journal of Shoulder and Elbow Surgery]01A - Beitrag in wissenschaftlicher Zeitschrift
- PublikationSpirits – un projet Interreg / ein Interreg-Projekt(regiosuisse – Netzwerkstelle Regionalentwicklung, 05.04.2019) de Wild, Michael; Renaud, Pierre07 - Audio- oder Videomaterial
- PublikationImplant surface modification by a controlled biomimetic approach(19.03.2019) Carino, Agnese; de Wild, Michael; Dalcanale, Federico06 - Präsentation
- PublikationThe new LassoLoop360° technique for biomechanically superior tissue grip(Springer, 2019) Müller, Sebastian; de Wild, Michael [in: Knee Surgery, Sports Traumatology, Arthroscopy]PurposeSuprapectoral tenodesis is a frequently used technique for treating pathologies of the long head of the biceps bra-chii (LHBB) tendon. However, so far, no Gold Standard treatment exist. Hence, the arthroscopic LassoLoop360 (LL360) technique is introduced aiming to provide secure fixation and improved biomechanical properties. It was hypothesized, that the LL360 technique would show superior biomechanical response to cyclic loading and ultimate load-to-failure testing compared to the commonly used simple Lasso Loop (SLL).MethodsTwenty-two porcine superficial flexor digitorum tendons were prepared using a No. 2 suture according to either the SLL or the LL360 technique. Displacement after cyclic loading (1.000 cycles) between 5 and 30 N, ultimate load-to-failure (ULTF), mode of failure as well as the construct stiffness were tested.ResultsSignificantly less displacement was found in the LL360 group (SLL 2.25 ± 0.51 mm; LL360 1.67 ± 0.37 mm; p = 0.01). Ultimate Load to Failure was significantly higher in the LL360 (168.6 ± 29.6 N) as compared to the SLL (124.1 ± 25.8 N, p = 0.02). The LL360 also revealed a significant higher stiffness compared to the SLL (SLL 13.1 ± 0.9 N/mm vs. LL360 19.1 ± 1.0 N/mm, p < 0.001). The most common mode of failure was the suture cutting through the tendon, with a significantly less suture cutting through for the LL360 compared with the SLL (p < 0.05).ConclusionThe LassoLoop360-technique offers superior biomechanical characteristics regarding the tendon-suture-interface compared to the SLL. In the initial healing phase, the suture-tendon-interface is the most vulnerable part of the tendon-suture-anchor construct, the aim of this new technique is to reduce this weakest part of the chain (Ponce et al., Am J Sports Med 39:188–194, 2011). This technique may therefore be beneficial for arthroscopic suprapectoral biceps tenodesis at the entrance of the bicipital groove01A - Beitrag in wissenschaftlicher Zeitschrift