Suchergebnisse
Hybrid ventilation in residential and office buildings
2023, Hoffmann, Caroline, Hauri, Claudia, Primas, Alex, Dorer, Viktor, Huber, Heinrich
This project is focused on hybrid ventilation systems, a combination of natural and mechanical ventilation in residential and office buildings. Especially in dwellings hybrid ventilation systems are quite common. For instance, this can be the frequently occurring combination of exhaust fans in bathroom and toilet and / or a range hood in the kitchen with window ventilation in the other rooms. Currently, these systems are part of the planning reality, however, there are neither planning aids nor focused building standards available. A recently completed research project documents the state of the scientific knowledge, identifies most common planning challenges, and thus provides the basis for future planning aids for hybrid ventilation. This paper sets out to define the term "hybrid ventilation", presents the most common hybrid ventilation systems in Switzerland and gives planning guidelines for current components of hybrid ventilation systems.
Energieeffiziente Büro- und Verwaltungsgebäude. Analysen und Erfahrungen im Kontext des Förderkonzepts Energieoptimiertes Bauen
2007-07-01, Voss, Karsten, Hoffmann, Caroline, Herkel, Sebastian, Wagner, Andeas, Löhnert, Günter
Der Beitrag berichtet über erreichte Kennwerte von Demonstrationsprojekten für Nichtwohngebäude im Neubau und Erfahrungen mit dem Einsatz von Wärmepumpen.
Development of a Multi-Criteria Decision-Making model to assist building designers in the choice of superficial construction systems in urban areas
2022-12-22, Dürr, Jonas, Geissler, Achim, Hoffmann, Caroline
An enormous range of building materials that is almost impossible to keep track of is available. The trend toward building densification in cities continues apace. Coupled with climate change, a situation is emerging that poses ecological as well as economic risks in terms of living comfort in public, urban spaces. Building designers need help (tools) to be able to address a wide range of requirements within their planning. The development of the Multi-Criteria Decision-Making (MCDM) model BASK (engl. “Construction Materials for Cities in Climate Change”) is presented. The goal of the model is to assist building designers in determining surface materials for wall, ground and roof construction and help determine the best compromise between environmental, economic, and building practice criteria. Currently available criteria are heat stress, visual reflectance, CO equivalents, electricity production, retrofitability, sound absorption, construction costs, and life span. The criteria can be weighted by the designer, resulting in a customized ranking of construction systems that best meets the designer’s prioritized criteria. The design of BASK basically allows for an extension of the criteria. The version of BASK described in this paper includes 10 construction systems covering a wide range of construction types focused on walls. The tool requires technical data for materials considered in construction systems included, which are made available via a data base. The scope of construction systems can also be extended in the future. Based on the restricted set of construction systems the results of a sensitivity analysis and initial validation are given.
EU-Richtlinie zur Gesamtenergieeffizienz von Gebäuden und nationale Umsetzung in der DIN 18599
2007, Hoffmann, Caroline, Kerschberger, Alfred, Brillinger, Martin, Binder, Markus
Thema des Buches ist die energetische Sanierung von Wohngebäuden im Bestand. Das Ziel des Buches ist es, das Realisierbare zu fördern und dem Planer den Überblick zu erleichtern. Es informiert umfassend über die richtigen Maßnahmen, mit denen ein Niedrigenergie-Standard auch bei Bestandsgebäuden erzielt werden kann.
Fensterlüfter in der Gebäudesanierung
2015-06, Hoffmann, Caroline, Geissler, Achim, Huber, Heinrich
Bei der energetischen Gebäudeerneuerung werden oftmals nur die Fenster ausge-tauscht. Wird keine mechanische Lüftungsanlage eingebaut, die einen kontinuierlichen Luftaustausch gewährleistet, können mit dichteren Fenstern Feuchtigkeitsprobleme entstehen. Abhilfe wäre mit dem Einbau von Fensterlüftern möglich. Dabei entsteht einerseits die Frage, ob diese alleine in der Lage sind den Feuchteschutzluftwechsel zu gewährleisten. Andererseits ist ungeklärt, wie hoch die möglichen Einsparungen sind, wenn man die Fensterlüfter mit einer Zu- und Abluftanlage mit Wärmerückgewinnung (WRG) vergleicht. Der Aufsatz behandelt Fensterlüfter ohne WRG in querbelüfteten Wohnungen. Es werden die Ergebnisse thermischer Simulationen einer typischen Wohnung im Mehrfamilienhaus vorgestellt.
Was wissen wir über den Gebäudebestand an Nichtwohn- und Bürogebäuden in Deutschland und Europa?– eine Literaturrecherche
2006, Hoffmann, Caroline
Der Artikel stellt die vorhandenen Daten zum Energieverbrauch und zum Bestand von Bürogebäuden in Deutschland und im europäischen Ausland zusammen. Da einige Angaben nicht speziell für Bürogebäude erhältlich sind, schließt die Betrachtung Nichtwohngebäude ein.