Effects of the test aerosol on the performance of periodic technical inspection particle counters

Type
01A - Journal article
Editors
Editor (Corporation)
Supervisor
Parent work
Journal of Aerosol Science
Special issue
DOI of the original publication
Link
Series
Series number
Volume
172
Issue / Number
Pages / Duration
106182
Patent number
Publisher / Publishing institution
Elsevier
Place of publication / Event location
Edition
Version
Programming language
Assignee
Practice partner / Client
Abstract
A new scheme for periodical technical inspection (PTI) of diesel-engine exhaust based on the measurement of particle number (PN) concentration was recently introduced in several European countries. PN concentration is measured directly at the tailpipe using portable particle counters known as PN-PTI. The technical specifications of these instruments are defined at a national level, and the type-examination and verification procedures differ considerably among European countries. In this study, we examined how the choice of test aerosol can affect the counting efficiency profile of the PN-PTI sensors, the majority of which are based on diffusion charging (DC). Carbonaceous aerosols were produced by combustion and spark discharge generators, sodium chloride (NaCl) particles were generated from aqueous solutions using several commercially available nebulizers and silver particles were produced by a silver particle generator. In most cases, the response of DC-based sensors depended strongly on the morphology of the test particles. Comparison with a Euro 3 diesel engine without a diesel particle filter (DPF) indicated that the combustion aerosols generated by combustion generators were the best proxy for soot emitted by diesel vehicle engines. On the contrary, the use of NaCl and spark discharge particles as test aerosols led in some cases to an over- or underestimation of the PN concentration by up to about a factor of two. Moreover, our results showed that the response of each type of DC-based sensors is individual and, as a result, it is impossible to determine a generally applicable factor to correct for the impact of the test aerosol properties. We recommend that the verification of PN-PTI instruments be preferably performed with soot particles produced by a combustion generator (identical or similar to the one used during the type-examination) in order to avoid corrections for the impact of the material on the response of the instruments.
Keywords
Project
Event
Exhibition start date
Exhibition end date
Conference start date
Conference end date
Date of the last check
ISBN
ISSN
0021-8502
Language
English
Created during FHNW affiliation
No
Strategic action fields FHNW
Publication status
Published
Review
Peer review of the complete publication
Open access category
Hybrid
License
'https://creativecommons.org/licenses/by-nc-nd/4.0/'
Citation
Vasilatou, K., Wälchli, C., Auderset, K., Burtscher, H., Hammer, T., Giechaskiel, B., & Melas, A. (2023). Effects of the test aerosol on the performance of periodic technical inspection particle counters. Journal of Aerosol Science, 172, 106182. https://doi.org/10.1016/j.jaerosci.2023.106182