Anthropomorphic lung phantom based validation of in-room proton therapy 4D-CBCT image correction for dose calculation

dc.accessRightsAnonymous*
dc.contributor.authorBondesson, David
dc.contributor.authorMeijers, Arturs
dc.contributor.authorJanssens, Guillaume
dc.contributor.authorRit, Simon
dc.contributor.authorRabe, Moritz
dc.contributor.authorKamp, Florian
dc.contributor.authorNiepel, Katharina
dc.contributor.authorOtter, Lydia A. den
dc.contributor.authorBoth, Stefan
dc.contributor.authorBrousmiche, Sebastien
dc.contributor.authorDinkel, Julien
dc.contributor.authorBelka, Claus
dc.contributor.authorParodi, Katia
dc.contributor.authorKurz, Christopher
dc.contributor.authorLandry, Guillaume
dc.contributor.authorKnopf, Antje
dc.date.accessioned2023-05-09T12:51:21Z
dc.date.available2023-05-09T12:51:21Z
dc.date.issued2022-02
dc.description.abstractPurpose Ventilation-induced tumour motion remains a challenge for the accuracy of proton therapy treatments in lung patients. We investigated the feasibility of using a 4D virtual CT (4D-vCT) approach based on deformable image registration (DIR) and motion-aware 4D CBCT reconstruction (MA-ROOSTER) to enable accurate daily proton dose calculation using a gantry-mounted CBCT scanner tailored to proton therapy. Methods Ventilation correlated data of 10 breathing phases were acquired from a porcine ex-vivo functional lung phantom using CT and CBCT. 4D-vCTs were generated by (1) DIR of the mid-position 4D-CT to the mid-position 4D-CBCT (reconstructed with the MA-ROOSTER) using a diffeomorphic Morphons algorithm and (2) subsequent propagation of the obtained mid-position vCT to the individual 4D-CBCT phases. Proton therapy treatment planning was performed to evaluate dose calculation accuracy of the 4D-vCTs. A robust treatment plan delivering a nominal dose of 60 Gy was generated on the average intensity image of the 4D-CT for an approximated internal target volume (ITV). Dose distributions were then recalculated on individual phases of the 4D-CT and the 4D-vCT based on the optimized plan. Dose accumulation was performed for 4D-vCT and 4D-CT using DIR of each phase to the mid position, which was chosen as reference. Dose based on the 4D-vCT was then evaluated against the dose calculated on 4D-CT both, phase-by-phase as well as accumulated, by comparing dose volume histogram (DVH) values (Dmean, D2%, D98%, D95%) for the ITV, and by a 3D-gamma index analysis (global, 3%/3 mm, 5 Gy, 20 Gy and 30 Gy dose thresholds). Results Good agreement was found between the 4D-CT and 4D-vCT-based ITV-DVH curves. The relative differences ((CT-vCT)/CT) between accumulated values of ITV Dmean, D2%, D95% and D98% for the 4D-CT and 4D-vCT-based dose distributions were −0.2%, 0.0%, −0.1% and −0.1%, respectively. Phase specific values varied between −0.5% and 0.2%, −0.2% and 0.5%, −3.5% and 1.5%, and −5.7% and 2.3%. The relative difference of accumulated Dmean over the lungs was 2.3% and Dmean for the phases varied between −5.4% and 5.8%. The gamma pass-rates with 5 Gy, 20 Gy and 30 Gy thresholds for the accumulated doses were 96.7%, 99.6% and 99.9%, respectively. Phase-by-phase comparison yielded pass-rates between 86% and 97%, 88% and 98%, and 94% and 100%. Conclusions Feasibility of the suggested 4D-vCT workflow using proton therapy specific imaging equipment was shown. Results indicate the potential of the method to be applied for daily 4D proton dose estimation.en_US
dc.identifier.doi10.1016/j.zemedi.2020.09.004
dc.identifier.issn0939-3889
dc.identifier.urihttps://irf.fhnw.ch/handle/11654/34922
dc.identifier.urihttps://doi.org/10.26041/fhnw-4842
dc.issue1en_US
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.relation.ispartofZeitschrift für Medizinische Physiken_US
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/en_US
dc.subjectTomographyen_US
dc.subjectCone-beamen_US
dc.subjectProton therapyen_US
dc.subject4D-vCTen_US
dc.subjectMotionen_US
dc.subjectThoraxen_US
dc.subject.ddc530 - Physiken_US
dc.titleAnthropomorphic lung phantom based validation of in-room proton therapy 4D-CBCT image correction for dose calculationen_US
dc.type01A - Beitrag in wissenschaftlicher Zeitschrift*
dc.volume32en_US
dspace.entity.typePublication
fhnw.InventedHereNoen_US
fhnw.IsStudentsWorknoen_US
fhnw.ReviewTypeAnonymous ex ante peer review of a complete publicationen_US
fhnw.affiliation.hochschuleHochschule für Life Sciencesde_CH
fhnw.affiliation.institutInstitut für Medizintechnik und Medizininformatikde_CH
fhnw.openAccessCategoryGolden_US
fhnw.pagination74-84en_US
fhnw.publicationStatePublisheden_US
relation.isAuthorOfPublication7c92bfb0-ba14-40c5-8233-6f259dffa6d2
relation.isAuthorOfPublication.latestForDiscovery7c92bfb0-ba14-40c5-8233-6f259dffa6d2
Dateien
Originalbündel
Gerade angezeigt 1 - 1 von 1
Lade...
Vorschaubild
Name:
1-s2.0-S0939388920300994-main.pdf
Größe:
2 MB
Format:
Adobe Portable Document Format
Beschreibung:
Lizenzbündel
Gerade angezeigt 1 - 1 von 1
Lade...
Vorschaubild
Name:
license.txt
Größe:
1.37 KB
Format:
Item-specific license agreed upon to submission
Beschreibung: