Anthropomorphic lung phantom based validation of in-room proton therapy 4D-CBCT image correction for dose calculation
dc.accessRights | Anonymous | * |
dc.contributor.author | Bondesson, David | |
dc.contributor.author | Meijers, Arturs | |
dc.contributor.author | Janssens, Guillaume | |
dc.contributor.author | Rit, Simon | |
dc.contributor.author | Rabe, Moritz | |
dc.contributor.author | Kamp, Florian | |
dc.contributor.author | Niepel, Katharina | |
dc.contributor.author | Otter, Lydia A. den | |
dc.contributor.author | Both, Stefan | |
dc.contributor.author | Brousmiche, Sebastien | |
dc.contributor.author | Dinkel, Julien | |
dc.contributor.author | Belka, Claus | |
dc.contributor.author | Parodi, Katia | |
dc.contributor.author | Kurz, Christopher | |
dc.contributor.author | Landry, Guillaume | |
dc.contributor.author | Knopf, Antje | |
dc.date.accessioned | 2023-05-09T12:51:21Z | |
dc.date.available | 2023-05-09T12:51:21Z | |
dc.date.issued | 2022-02 | |
dc.description.abstract | Purpose Ventilation-induced tumour motion remains a challenge for the accuracy of proton therapy treatments in lung patients. We investigated the feasibility of using a 4D virtual CT (4D-vCT) approach based on deformable image registration (DIR) and motion-aware 4D CBCT reconstruction (MA-ROOSTER) to enable accurate daily proton dose calculation using a gantry-mounted CBCT scanner tailored to proton therapy. Methods Ventilation correlated data of 10 breathing phases were acquired from a porcine ex-vivo functional lung phantom using CT and CBCT. 4D-vCTs were generated by (1) DIR of the mid-position 4D-CT to the mid-position 4D-CBCT (reconstructed with the MA-ROOSTER) using a diffeomorphic Morphons algorithm and (2) subsequent propagation of the obtained mid-position vCT to the individual 4D-CBCT phases. Proton therapy treatment planning was performed to evaluate dose calculation accuracy of the 4D-vCTs. A robust treatment plan delivering a nominal dose of 60 Gy was generated on the average intensity image of the 4D-CT for an approximated internal target volume (ITV). Dose distributions were then recalculated on individual phases of the 4D-CT and the 4D-vCT based on the optimized plan. Dose accumulation was performed for 4D-vCT and 4D-CT using DIR of each phase to the mid position, which was chosen as reference. Dose based on the 4D-vCT was then evaluated against the dose calculated on 4D-CT both, phase-by-phase as well as accumulated, by comparing dose volume histogram (DVH) values (Dmean, D2%, D98%, D95%) for the ITV, and by a 3D-gamma index analysis (global, 3%/3 mm, 5 Gy, 20 Gy and 30 Gy dose thresholds). Results Good agreement was found between the 4D-CT and 4D-vCT-based ITV-DVH curves. The relative differences ((CT-vCT)/CT) between accumulated values of ITV Dmean, D2%, D95% and D98% for the 4D-CT and 4D-vCT-based dose distributions were −0.2%, 0.0%, −0.1% and −0.1%, respectively. Phase specific values varied between −0.5% and 0.2%, −0.2% and 0.5%, −3.5% and 1.5%, and −5.7% and 2.3%. The relative difference of accumulated Dmean over the lungs was 2.3% and Dmean for the phases varied between −5.4% and 5.8%. The gamma pass-rates with 5 Gy, 20 Gy and 30 Gy thresholds for the accumulated doses were 96.7%, 99.6% and 99.9%, respectively. Phase-by-phase comparison yielded pass-rates between 86% and 97%, 88% and 98%, and 94% and 100%. Conclusions Feasibility of the suggested 4D-vCT workflow using proton therapy specific imaging equipment was shown. Results indicate the potential of the method to be applied for daily 4D proton dose estimation. | en_US |
dc.identifier.doi | 10.1016/j.zemedi.2020.09.004 | |
dc.identifier.issn | 0939-3889 | |
dc.identifier.uri | https://irf.fhnw.ch/handle/11654/34922 | |
dc.identifier.uri | https://doi.org/10.26041/fhnw-4842 | |
dc.issue | 1 | en_US |
dc.language.iso | en | en_US |
dc.publisher | Elsevier | en_US |
dc.relation.ispartof | Zeitschrift für Medizinische Physik | en_US |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | en_US |
dc.subject | Tomography | en_US |
dc.subject | Cone-beam | en_US |
dc.subject | Proton therapy | en_US |
dc.subject | 4D-vCT | en_US |
dc.subject | Motion | en_US |
dc.subject | Thorax | en_US |
dc.subject.ddc | 530 - Physik | en_US |
dc.title | Anthropomorphic lung phantom based validation of in-room proton therapy 4D-CBCT image correction for dose calculation | en_US |
dc.type | 01A - Beitrag in wissenschaftlicher Zeitschrift | * |
dc.volume | 32 | en_US |
dspace.entity.type | Publication | |
fhnw.InventedHere | No | en_US |
fhnw.IsStudentsWork | no | en_US |
fhnw.ReviewType | Anonymous ex ante peer review of a complete publication | en_US |
fhnw.affiliation.hochschule | Hochschule für Life Sciences | de_CH |
fhnw.affiliation.institut | Institut für Medizintechnik und Medizininformatik | de_CH |
fhnw.openAccessCategory | Gold | en_US |
fhnw.pagination | 74-84 | en_US |
fhnw.publicationState | Published | en_US |
relation.isAuthorOfPublication | 7c92bfb0-ba14-40c5-8233-6f259dffa6d2 | |
relation.isAuthorOfPublication.latestForDiscovery | 7c92bfb0-ba14-40c5-8233-6f259dffa6d2 |
Dateien
Originalbündel
1 - 1 von 1
Lade...
- Name:
- 1-s2.0-S0939388920300994-main.pdf
- Größe:
- 2 MB
- Format:
- Adobe Portable Document Format
- Beschreibung:
Lizenzbündel
1 - 1 von 1
Lade...
- Name:
- license.txt
- Größe:
- 1.37 KB
- Format:
- Item-specific license agreed upon to submission
- Beschreibung: