Evaluation of calcium dihydroxide- and silver-coated implants in the rat tibia

dc.accessRightsAnonymous
dc.audienceScience
dc.contributor.authorHarrasser, Norbert
dc.contributor.authorde Wild, Michael
dc.contributor.authorGorkotte, Johannes
dc.contributor.authorObermeier, Andreas
dc.contributor.authorFeihl, Susanne
dc.date.accessioned2017-01-23T06:50:36Z
dc.date.available2017-01-23T06:50:36Z
dc.date.issued2016-11-02
dc.description.abstractSilver ions (Ag+) have strong antibacterial effects, and silver-coated materials are in widespread clinical use. However, the application of silver-coated medical devices is not without concerns: its use with direct bone contact is not established, and systemic toxic side effects of released Ag+ have been described. Therefore, alternative bactericidal coatings with a more localized way of acting - e.g., calcium dihydroxide, Ca(OH)2 (CH) - would be advantageous. A new rat model of the animal's tibial metaphysis was developed. In the left proximal tibiae of 36 male Wistar rats, titanium screws were implanted. The screws were coated with hydroxyapatite (HA; 12 animals: group I), low-dosed HA silver (HA-Ag; 12 animals: group II) and CH (12 animals: group III). After 6 weeks, all rats were sacrificed. The implants were evaluated for morphological changes on their surfaces, by light microscopy, scanning electron microscopy and energy-dispersive X-ray spectroscopy; for osteointegration, by measurement of resistance to removal; and for bacterial colonization, by quantitative culture analysis. Additionally, the tibial bone was investigated histologically for signs of osteomyelitis and sonicated to detect bacterial loads. (i) No microbiological or histological signs of infection could be determined on any of the screws or the surrounding bone. (ii) The bone-implant interface analysis revealed extensive bone formation and direct bone-implant contact on all HA, HA-Ag and HA-CH coated screws. (iii) HA and HA-Ag were partially, and CH was fully, degraded on the screw coating, allowing host bone to osteointegrate.
dc.identifier.doi10.5301/jabfm.5000323
dc.identifier.issn2280-0800
dc.identifier.issn2280-8000
dc.identifier.urihttp://hdl.handle.net/11654/24046
dc.issue4
dc.language.isoen
dc.publisherSAGEen_US
dc.relation.ispartofJournal of Applied Biomaterials & Functional Materialsen_US
dc.titleEvaluation of calcium dihydroxide- and silver-coated implants in the rat tibia
dc.type01A - Beitrag in wissenschaftlicher Zeitschrift
dc.volume14
dspace.entity.typePublication
fhnw.InventedHereYes
fhnw.IsStudentsWorkno
fhnw.PublishedSwitzerlandNo
fhnw.ReviewTypeAnonymous ex ante peer review of a complete publication
fhnw.affiliation.hochschuleHochschule für Life Sciencesde_CH
fhnw.affiliation.institutInstitut für Medizintechnik und Medizininformatikde_CH
fhnw.paginatione441-e448
fhnw.publicationOnlineJa
fhnw.publicationStatePublished
relation.isAuthorOfPublication135938a9-969d-4ea3-9bb2-7ff1d77554cb
relation.isAuthorOfPublication.latestForDiscovery135938a9-969d-4ea3-9bb2-7ff1d77554cb
Dateien