lnstitut für Sensorik und Elektronik
Dauerhafte URI für die Sammlunghttps://irf.fhnw.ch/handle/11654/28068
Listen
6 Ergebnisse
Ergebnisse nach Hochschule und Institut
Publikation A dual-wavelength photothermal aerosol absorption monitor. Design, calibration and performance(Copernicus, 2022) Drinovec, Luka; Jagodič, Uroš; Pirker, Luka; Škarabot, Miha; Kurtjak, Mario; Vidović, Kristijan; Ferrero, Luca; Visser, Bradley; Röhrbein, Jannis; Weingartner, Ernest; Kalbermatter, Daniel M.; Vasilatou, Konstantina; Bühlmann, Tobias; Pascale, Celine; Müller, Thomas; Wiedensohler, Alfred; Močnik, GrišaThere exists a lack of aerosol absorption measurement techniques with low uncertainties and without artefacts. We have developed the two-wavelength Photothermal Aerosol Absorption Monitor (PTAAM-2λ), which measures the aerosol absorption coefficient at 532 and 1064 nm. Here we describe its design, calibration and mode of operation and evaluate its applicability, limits and uncertainties. The 532 nm channel was calibrated with ∼ 1 µmol mol−1 NO2, whereas the 1064 nm channel was calibrated using measured size distribution spectra of nigrosin particles and a Mie calculation. Since the aerosolized nigrosin used for calibration was dry, we determined the imaginary part of the refractive index of nigrosin from the absorbance measurements on solid thin film samples. The obtained refractive index differed considerably from the one determined using aqueous nigrosin solution. PTAAM-2λ has no scattering artefact and features very low uncertainties: 4 % and 6 % for the absorption coefficient at 532 and 1064 nm, respectively, and 9 % for the absorption Ångström exponent. The artefact-free nature of the measurement method allowed us to investigate the artefacts of filter photometers. Both the Aethalometer AE33 and CLAP suffer from cross sensitivity to scattering – this scattering artefact is most pronounced for particles smaller than 70 nm. We observed a strong dependence of the filter multiple scattering parameter on the particle size in the 100–500 nm range. The results from the winter ambient campaign in Ljubljana showed similar multiple scattering parameter values for ambient aerosols and laboratory experiments. The spectral dependence of this parameter resulted in AE33 reporting the absorption Ångström exponent for different soot samples with values biased 0.23–0.35 higher than the PTAAM-2λ measurement. Photothermal interferometry is a promising method for reference aerosol absorption measurements.01A - Beitrag in wissenschaftlicher ZeitschriftPublikation Comparing black carbon and aerosol absorption measuring instruments – a new system using lab-generated soot coated with controlled amounts of secondary organic matter(Copernicus, 2022) Kalbermatter, Daniel M.; Močnik, Griša; Drinovec, Luka; Visser, Bradley; Röhrbein, Jannis; Oscity, Matthias; Weingartner, Ernest; Hyvärinen, Antti-Pekka; Vasilatou, KonstantinaWe report on an inter-comparison of black-carbon- and aerosol-absorption-measuring instruments with laboratory-generated soot particles coated with controlled amounts of secondary organic matter (SOM). The aerosol generation setup consisted of a miniCAST 5201 Type BC burner for the generation of soot particles and a new automated oxidation flow reactor based on the micro smog chamber (MSC) for the generation of SOM from the ozonolysis of α-pinene. A series of test aerosols was generated with elemental to total carbon (EC / TC) mass fraction ranging from about 90 % down to 10 % and single-scattering albedo (SSA at 637 nm) from almost 0 to about 0.7. A dual-spot Aethalometer AE33, a photoacoustic extinctiometer (PAX, 870 nm), a multi-angle absorption photometer (MAAP), a prototype photoacoustic instrument, and two prototype photo-thermal interferometers (PTAAM-2λ and MSPTI) were exposed to the test aerosols in parallel. Significant deviations in the response of the instruments were observed depending on the amount of secondary organic coating. We believe that the setup and methodology described in this study can easily be standardised and provide a straightforward and reproducible procedure for the inter-comparison and characterisation of both filter-based and in situ black-carbon-measuring (BC-measuring) instruments based on realistic test aerosols.01A - Beitrag in wissenschaftlicher ZeitschriftPublikation Coated soot particles with tunable, well-controlled properties generated in the laboratory with a miniCAST BC and a micro smog chamber(Elsevier, 28.05.2021) Ess, Michaela N.; Bertò, Michele; Keller, Alejandro; Gysel, Martin; Vasilatou, KonstantinaA Micro Smog Chamber (MSC) was coupled for the first time with a miniCAST 5201 Type BC combustion generator with the aim to produce a series of stable and reproducible model aerosols simulating the physical properties of combustion particles present in ambient air. With this setup it was possible to generate particles ranging from “fresh” soot (single scattering albedo SSA≤0.05, absorption Ångström exponent AAE close to 1, high EC/TC mass fraction (approximately 90%) and mobility diameter typically <100 nm) to “aged” soot with different amounts of organic coating. The “aged” soot particles could grow up to 200 nm and exhibited high SSA (up to 0.7 at λ = 870 nm), an increased AAE (up to 1.7) and low EC/TC mass fraction (down to <10%). The ageing was achieved by coating the soot particles with increasing amounts of secondary organic matter (SOM) formed by the photo-oxidation of α-pinene or mesitylene in the MSC. Thereby, the SSA and AAE increased with coating thickness, while the EC/TC mass fraction decreased. Over the experimental period of 2 h, the generation of the “aged” soot aerosols was stable with a standard deviation in particle size and number concentration of <1% and <6%, respectively. The day-to-day reproducibility was also satisfactory: with α-pinene as SOM precursor the variability (standard deviation) in particle size was <2% and in the AAE and SSA < 6%. Particle number concentrations up to 106 cm−3 and mass concentrations up to 15 mg/m3 (depending on particle size and SOM amount) could be generated, much higher than what has been reported with other oxidation flow reactors. The generated carbonaceous aerosols could find useful applications in the field of aerosol instrument calibration, particularly in the standardization of filter-based absorption photometers under controlled conditions.01A - Beitrag in wissenschaftlicher ZeitschriftPublikation The organic coating unit, an all-in-one system for reproducible generation of secondary organic aerosol(22.06.2022) Keller, Alejandro; Specht, Patrick; Steigmeier, Peter; Kalbermatter, Daniel; Hammer, Tobias; Vasilatou, Konstantina; Wolfer, Kate; Resch, Julian; Kalberer, Markus06 - PräsentationPublikation The organic coating unit, an all-in-one system for reproducible generation of secondary organic aerosol(06.09.2022) Keller, Alejandro; Kalbermatter, Daniel; Specht, Patrick; Steigmeier, Peter; Wolfer, Katherin; Resch, Julian; Kalberer, Markus; Hammer, Tobias; Vasilatou, Konstantina06 - PräsentationPublikation The organic coating unit, an all-in-one system for reproducible generation of secondary organic matter aerosol(Taylor & Francis, 18.08.2022) Keller, Alejandro; Kalbermatter, Daniel M.; Wolfer, Kate; Specht, Patrick; Steigmeier, Peter; Resch, Julian; Kalberer, Markus; Hammer, Tobias; Vasilatou, KonstantinaWe report on a novel automated oxidation flow reactor to generate a wide variety of organic aerosol samples. The instrument is equipped with a humidifier, a dosing system for volatile organic precursors and an oxidation flow reactor (OFR) for generation of secondary organic matter (SOM). The instrument, known as organic coating unit (OCU), can produce homogeneously nucleated SOM particles or, used in combination with a standard combustion generator (e.g., a diffusion flame soot generator or any other seed particle), particles coated with a controlled amount of SOM. The physical and chemical properties of the generated particles can be controlled in a simple manner by selecting through a touch-screen target values for parameters, such as organic gaseous precursor concentration, humidity, and UV (ultraviolet) light intensity. Parameters and measured quantities are automatically stored in text files for easy export and analysis. Furthermore, we provide stable operation conditions and characterize the physicochemical properties of the generated aerosols with an array of methods, including transmission electron microscopy (TEM), thermal-optical analysis and liquid chromatography coupled with mass spectrometry (LC-MS). This all-in-one instrument is robust, compact, portable, and user-friendly, making it ideal for laboratory or field-based aerosol studies.01A - Beitrag in wissenschaftlicher Zeitschrift