Institut für Medizintechnik und Medizininformatik

Dauerhafte URI für die Sammlunghttps://irf.fhnw.ch/handle/11654/23

Listen

Ergebnisse nach Hochschule und Institut

Gerade angezeigt 1 - 3 von 3
  • Vorschaubild
    Publikation
    Effect of printing parameters on mechanical performance of material-extrusion 3D-printed PEEK specimens at the point-of-care
    (MDPI, 17.01.2023) Zarean, Paridokht; Zarean, Parichehr; de Wild, Michael; Thieringer, Florian M.; Sharma, Neha; Seiler, Daniel; Malgaroli, Patrick
    Additive manufacturing (AM) of polyetheretherketone (PEEK) biomaterials using the material-extrusion (MEX) method has been studied for years. Because of the challenging manufacturing process, precisely controlling printing parameters is crucial. This study aimed to investigate the effects of printing parameters such as orientation and position of printing on mechanical properties. Thus, 34 samples were printed using PEEK filament and the MEX process. Samples were divided into two main groups (A,B) according to their printing orientations (A: groups 1–3) and positions on the build plate (B: groups 4–8). Mechanical tensile tests were performed to evaluate the effects of different printing orientations and positions on mechanical properties. The means of the tensile modulus in samples 3D-printed in XY (group 1), XZ (group 2), and ZX (group 3) orientations were not significantly different (p-value = 0.063). Groups 1 and 2 had smaller distributions than group 3 in the means of tensile strength. The t-test showed that the overall means of the measurements in groups 4–8 did not differ significantly (p-value = 0.315). The tensile tests indicated that printing in vertical and horizontal orientations had no significant influence on mechanical properties. There were no significant differences in mechanical strength between top/bottom printed samples in five different lateral positions. Reliability of printing with good mechanical properties could be a step forward to manufacturing patient-specific implants.
    01A - Beitrag in wissenschaftlicher Zeitschrift
  • Vorschaubild
    Publikation
    Topology-optimized patient-specific osteosynthesis plates
    (De Gruyter, 02.09.2022) Maintz, Michaela; Seiler, Daniel; Thieringer, Florian M.; de Wild, Michael
    Patient-specific osteosynthesis plates can be used to reduce complications related to bone fracture treatment, such as infection, malocclusion and fatigue fractures of plates and screws. However, the implant design process is tedious. We propose a semi-automatic workflow to computationally design patient-specific titanium osteosynthesis plates for mandibular angle fractures. In this process, the plate stiffness is maximized while the mass is reduced. Two plate designs with different numbers of screw holes (implant #1 with four holes, implant #2 with eight holes) were generated with identical topology optimization settings and compared in a finite element model simulating various biomechanical masticatory loads. Differences in von Mises stresses in the implants and screws were observed. The load case of clenching the jaw on the opposite side of the fracture showed the highest stress distribution in implant #1 and higher peak stresses in implant #2. Stress concentrations were observed in sharp corners of the implant and could be reduced using local stress-based topology optimization. We conclude that the design process is an effective method to generate patientspecific implants.
    01A - Beitrag in wissenschaftlicher Zeitschrift
  • Vorschaubild
    Publikation
    Fabrication and characterization of PCL/HA filament as a 3D printing material using thermal extrusion technology for bone tissue engineering
    (MDPI, 11.02.2022) Wang, Fengze; Tankus, Esma Bahar; Santarella, Francesco; Rohr, Nadja; Sharma, Neha; Märtin, Sabrina; Michalscheck, Mirja; Cao, Shuaishuai; Maintz, Michaela; Thieringer, Florian M.
    The most common three-dimensional (3D) printing method is material extrusion, where a pre-made filament is deposited layer-by-layer. In recent years, low-cost polycaprolactone (PCL) material has increasingly been used in 3D printing, exhibiting a sufficiently high quality for consideration in cranio-maxillofacial reconstructions. To increase osteoconductivity, prefabricated filaments for bone repair based on PCL can be supplemented with hydroxyapatite (HA). However, few reports on PCL/HA composite filaments for material extrusion applications have been documented. In this study, solvent-free fabrication for PCL/HA composite filaments (HA 0%, 5%, 10%, 15%, 20%, and 25% weight/weight PCL) was addressed, and parameters for scaffold fabrication in a desktop 3D printer were confirmed. Filaments and scaffold fabrication temperatures rose with increased HA content. The pore size and porosity of the six groups’ scaffolds were similar to each other, and all had highly interconnected structures. Six groups’ scaffolds were evaluated by measuring the compressive strength, elastic modulus, water contact angle, and morphology. A higher amount of HA increased surface roughness and hydrophilicity compared to PCL scaffolds. The increase in HA content improved the compressive strength and elastic modulus. The obtained data provide the basis for the biological evaluation and future clinical applications of PCL/HA material.
    01A - Beitrag in wissenschaftlicher Zeitschrift