Geissler, Achim

Lade...
Profilbild
E-Mail-Adresse
Geburtsdatum
Projekt
Organisationseinheiten
Berufsbeschreibung
Nachname
Geissler
Vorname
Achim
Name
Geissler, Achim

Suchergebnisse

Gerade angezeigt 1 - 10 von 18
  • Publikation
    Development of a Multi-Criteria Decision-Making model to assist building designers in the choice of superficial construction systems in urban areas
    (SAGE, 22.12.2022) Dürr, Jonas; Geissler, Achim; Hoffmann, Caroline [in: Journal of Building Physics]
    An enormous range of building materials that is almost impossible to keep track of is available. The trend toward building densification in cities continues apace. Coupled with climate change, a situation is emerging that poses ecological as well as economic risks in terms of living comfort in public, urban spaces. Building designers need help (tools) to be able to address a wide range of requirements within their planning. The development of the Multi-Criteria Decision-Making (MCDM) model BASK (engl. “Construction Materials for Cities in Climate Change”) is presented. The goal of the model is to assist building designers in determining surface materials for wall, ground and roof construction and help determine the best compromise between environmental, economic, and building practice criteria. Currently available criteria are heat stress, visual reflectance, CO equivalents, electricity production, retrofitability, sound absorption, construction costs, and life span. The criteria can be weighted by the designer, resulting in a customized ranking of construction systems that best meets the designer’s prioritized criteria. The design of BASK basically allows for an extension of the criteria. The version of BASK described in this paper includes 10 construction systems covering a wide range of construction types focused on walls. The tool requires technical data for materials considered in construction systems included, which are made available via a data base. The scope of construction systems can also be extended in the future. Based on the restricted set of construction systems the results of a sensitivity analysis and initial validation are given.
    01A - Beitrag in wissenschaftlicher Zeitschrift
  • Publikation
    Schwerkraftlüftung – Low-tech Lüftung für innenliegende Bäder in einem Mehrfamilienhaus
    (Brenet, 12.09.2022) Hall, Monika; Geissler, Achim; Gerber, Vincent; Sattler, Michael; Bichsel, Jürg; Rudel, Roman; Steiger, Olivier; Tillenkamp, Frank [in: SustainDesign user friendly and resilient design with appropriate technology]
    Über ein detailliertes Monitoring wird die Wirksamkeit der Schwerkraftlüftung in acht innenliegenden Bädern in einem Mehrfamilien Neubau bestimmt. Jeweils vier Bäder liegen übereinander. Jedes Bad verfügt über ein eigenes Zu- und Abluftrohr. Frischluft wird auf Kellerhöhe gefasst und die Fortluft auf Firsthöhe abgegeben. Weil bei der Schwerkraftlüftung der Luftaustausch auf Grund von Druckunterschieden am Gebäude erfolgt, ist er nicht bzw. kaum steuerbar und saisonal unterschiedlich. Daher erfolgt das Monitoring über ein komplettes Jahr, um das Verhalten in allen Jahreszeiten zu erfassen. Die Messungen zwischen März und Juli 2022 zeigen, dass sich die rel. Luftfeuchtigkeit der Bäder im Mittel zwischen ca. 45-65 % bewegt. Fallbetrachtungen zeigen, dass kurzzeitige hohe Feuchtebelastungen (bis ~98 % bei einem Duschvorgang) nach ca. 30 min bei offener Badezimmertüre und mindestens einem geöffneten Fenster und entsprechender, geöffneter Zimmertüre wieder auf ca. 60 % reduziert sind (manuelle Fensterlüftung, Juni). Bei einer geschlossenen Badezimmertüre dauert es infolge der Schwerkraftlüftung ca. 2.5 Stunden, um nach zwei Duschvorgängen auf 60 % rel. Luftfeuchtigkeit zu sinken (März). Letztgenannter Fall zeigt, dass durch die Schwerkraftlüftung eine ausreichende Feuchteabfuhr erfolgt.
    04B - Beitrag Konferenzschrift
  • Publikation
    Baumaterialien für Städte im Klimawandel. Materialkatalog mit Empfehlungen
    (Bundesamt für Wohnungswesen (BWO), 16.06.2022) Hoffmann, Caroline; Geissler, Achim
    Städte erwärmen sich stärker als ländliche Gegenden. Dieser Materialkatalog zeigt auf, mit welchen Baumaterialien sich die Umwelt weniger erwärmt. Das Nachschlagewerk richtet sich an Planerinnen und Planer sowie Bauträgerschaften, die Gebäude im urbanen Raum erstellen oder sanieren.
    05 - Forschungs- oder Arbeitsbericht
  • Publikation
    Prebound, Rebound, Performance Gap – Was stimmt nicht zwischen dem Energiebedarf und dem Energieverbrauch von Wohngebäuden?
    (PetzDruck, 28.04.2022) Hoffmann, Caroline; Geissler, Achim [in: 6. Internationale Fachtagung Bauphysik & Gebäudetechnik (BTG)]
    Es geht um die Differenz zwischen Heizwärmebedarf und Heizwärmeverbrauch bei Wohngebäuden.
    04B - Beitrag Konferenzschrift
  • Publikation
    "Prebound, Rebound, Performance Gap - Was stimmt nicht zwischen dem Energiebedarf und dem Energieverbrauch von Wohngebäuden?"
    (28.04.2022) Hoffmann, Caroline; Geissler, Achim
    - Gemessener Verbrauch und berechneter Heizwärmebedarf bei 33 unsanierten Bestandsgebäuden - Anwendung SIA 380/1 für unsanierte Bestandsgebäude - Gründe für die Abweichungen zwischen Heizwärmeverbrauch und -Bedarf - Vorschläge zur Anpassung einzelner Faktoren in der Berechnung
    06 - Präsentation
  • Publikation
    Comparison of flexibility factors and introduction of a flexibility classification using advanced heat pump control
    (MDPI, 13.12.2021) Hall, Monika; Geissler, Achim [in: Energies]
    With the increasing use of renewable energy, the energy flexibility of buildings becomes increasingly important regarding grid support. Therefore, there is a need to describe this flexibility in a concise manner. For the characterization of building energy flexibility, flexibility factors can be used. The comparison of a selection of existing flexibility factors shows that they are not easy to use or understand for designers and users. A simplification is necessary. The aim of this study is to introduce a flexibility classification that is easy to understand and shows in an easy way if a building already uses the lowest energy cost level or if further improvement is possible. The classification expresses the annual energy costs in colored classes: green (class A) for lowest up to red (class D) for highest level. Basically, the flexibility classes can be derived for any metric of interest, in this paper examples are shown for energy costs and CO2eq emissions. The results given are based on the simulation of load management scenarios with different penalty signals applied for the heat pump operation of a residential building.
    01A - Beitrag in wissenschaftlicher Zeitschrift
  • Publikation
    Baumaterialien für Städte im Klimawandel – ein Materialkatalog mit Empfehlungen
    (25.11.2021) Hoffmann, Caroline; Geissler, Achim; Mutti, Miriam; Wicki, Andreas; Schwager, Franziska
    Die gewählten Baumaterialien haben Auswirkungen auf das städtische Mikroklima. Zusätzlich beeinflussen die Materialisierung der Fassade und der Bodenbeläge des Gebäudeumfeldes die Umwelt z.B. im Hinblick auf die Versickerungsfähigkeit, die Akustik oder die Blendung. Der Vortrag gibt einen Einblick in den Katalog und Empfehlungen zur Materialienwahl.
    06 - Präsentation
  • Publikation
    Comparison of flexibility factors for a residential building
    (IOP Publishing, 18.11.2021) Hall, Monika; Geissler, Achim [in: Journal of Physics: Conference Series]
    Buildings that are able to shift their loads without comfort restraints are important for the ongoing transformation of the power supply. This flexibility potential can be expressed in flexibility factors. The usefulness of four factors is investigated based on load control for the heat pump of a small apartment building according to electricity prices (high/low tariffs, spot market prices), CO2eq emissions share in the grid and a restricted operation period during daytime. The calculation methodology of the presented flexibility factors GSC, RIP, FF and FI is very different. RIP and FF are preferable because they have defined valid ranges which makes them easier to understand. Current electricity prices force the heat pump operation mainly into the night. The optimization of CO2eq emissions encourages operation mainly during the day. The optimization goals costs or CO2eq emissions thus lead to opposing heat pump operation times and can currently therefore not both be met simultaneously.
    01A - Beitrag in wissenschaftlicher Zeitschrift
  • Publikation
    Baumaterialien für Städte im Klimawandel – ein Materialkatalog mit Empfehlungen
    (27.10.2021) Hoffmann, Caroline; Geissler, Achim; Mutti, Miriam; Wicki, Andreas; Schwager, Franziska
    Die gewählten Baumaterialien haben Auswirkungen auf das städtische Mikroklima. Zusätzlich beeinflussen die Materialisierung der Fassade und der Bodenbeläge des Gebäudeumfeldes die Umwelt z.B. im Hinblick auf die Versickerungsfähigkeit, die Akustik oder die Blendung. Der Vortrag gibt einen Einblick in den Katalog und Empfehlungen zur Materialienwahl.
    06 - Präsentation
  • Publikation
    Die zerstörungsfreie Messung des U-Wertes von Aussenbauteilen. Eine Anwendungshilfe
    (EnergieSchweiz, 01.10.2021) Hoffmann, Caroline; Geissler, Achim
    U-Wert Messungen vor Ort eigenen sich für Gebäude, bei denen die Konstruktion unbekannt ist und eine zerstörungsfreie, sichere Aussage zu den thermischen Eigenschaften getroffen werden soll. Die entsprechenden Messgeräte sind am Markt erhältlich und zielen auf eine breite Anwendung. Ziel des Projektes ist es, eine praxisorientierte Anwendungshilfe für die U-Wert Messung vor Ort zu erstellen. Als Basis dienen in-situ U-Wert Messungen und vergleichende Messungen im Labor, die mit drei unterschiedlichen Messgeräten durchgeführt werden. Ergänzend dazu werden Simulationen erstellt und Kontakt- und Haftmittel zur Befestigung der Sensoren an den zu messenden Bauteilen getestet. Untersucht werden schwere, homogene Bauteile, damit beziehen sich die Hinweise hauptsächlich auf diesen Bauteiltyp.
    05 - Forschungs- oder Arbeitsbericht