Evaluation of VOC measurements in the EXPOLIS study

Typ
01A - Beitrag in wissenschaftlicher Zeitschrift
Herausgeber:innen
Herausgeber:in (Körperschaft)
Betreuer:in
Übergeordnetes Werk
Journal of Environmental Monitoring
Themenheft
DOI der Originalpublikation
Link
Reihe / Serie
Reihennummer
Jahrgang / Band
3
Ausgabe / Nummer
1
Seiten / Dauer
159-165
Patentnummer
Verlag / Herausgebende Institution
Royal Society of Chemistry
Verlagsort / Veranstaltungsort
London
Auflage
Version
Programmiersprache
Abtretungsempfänger:in
Praxispartner:in/Auftraggeber:in
Zusammenfassung
Personal exposures and microenvironment concentrations of 30 target VOCs were measured for 401 participants living in five European cities as a part of the EXPOLIS (Air Pollution Exposure Distributions within Adult Urban Populations in Europe) study. Measurements in Basel used an active charcoal (Carbotech) adsorbent as opposed to the Tenax TA used in the other study centres. In addition, within each centre, personal and microenvironment VOC sampling required different sampling pumps and, because of different sampling durations, different sampling flow rates. Thus, careful testing of the sampling and analysis procedures was required to ensure accuracy and comparability of collected data. Monitor comparison tests using Tenax TA showed a mean VOC concentration ratio of 0.95 between the personal and microenvironment monitors. The LODs for the target VOCs using Tenax TA ranged from 0.7 to 5.2 µg m−3. The LODs for the 14 target compounds quantifiable using Carbotech ranged from 0.9 to 3.2 µg m−3. Tenax TA field blanks showed no remarkable contamination with the target VOCs, except benzaldehyde, a known artefact with this adsorbent. Thus, the diffusion barrier system used prevented contamination of Tenax TA samples by passive diffusion during non-sampling periods. Duplicate and parallel evaluations of the Tenax TA and Carbotech showed an average difference of <17% in VOC concentrations within the sampling methods, but a systematic difference between the methods (Tenax TA ∶ Carbotech concentration ratio = 1.18–2.36). These field evaluations and quality assurance tests showed that interpretation and comparison of the results in any VOC monitoring exercise should be done on a compound by compound basis. It is also apparent that carefully planned and realised QA and QC (QA/QC) procedures are needed in multi-centre studies, where a common sampling method and laboratory analysis technique are not used, to strengthen and simplify the interpretation of observed VOC levels between participating centres.
Schlagwörter
Fachgebiet (DDC)
300 - Sozialwissenschaften, Soziologie, Anthropologie
610 - Medizin und Gesundheit
Projekt
Veranstaltung
Startdatum der Ausstellung
Enddatum der Ausstellung
Startdatum der Konferenz
Enddatum der Konferenz
Datum der letzten Prüfung
ISBN
ISSN
1464-0325
1464-0333
Sprache
Englisch
Während FHNW Zugehörigkeit erstellt
Nein
Zukunftsfelder FHNW
Publikationsstatus
Veröffentlicht
Begutachtung
Peer-Review der ganzen Publikation
Open Access-Status
Closed
Lizenz
Zitation
JURVELIN, Jouni, Rufus EDWARDS, Kristina SAARELA, Jutta LAINE­-YLIJOKI, Maurizio DE BORTOLI, Lucy BAYER-OGLESBY, Kurt SCHLÄPFER, Lambros GEORGOULIS, Eva TISCHEROVA, Otto HÄNNINEN und Matti JANTUNEN, 2001. Evaluation of VOC measurements in the EXPOLIS study. Journal of Environmental Monitoring. 2001. Bd. 3, Nr. 1, S. 159–165. DOI 10.1039/B007600G. Verfügbar unter: https://irf.fhnw.ch/handle/11654/45834